Chris R.

Chris R.

START UP ON 2 UNITS ROOM IS 69 DEGREES DURRELL WILL MONITOR AND MAKE SURE THE ROOM HOLDS TEMP AND PUMPS FUNCTION PROPERLY NO CHARGE PER BOYD

Near N 54th St, Chandler, AZ 85226
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON GAS FURNACE AND CONVENTIONAL AC TESTED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS FOR PERFORMANCE VERIFIED TEMPERATURE RISE IN HEATING TIGHTENED ELECTRICAL CONNECTIONS TESTED PRESSURE SAFETY SWITCH TEATED FLAME SENSOR SAFETY CHECKED ROLLOUT SAFETY FOR PERFORMANCE VERIFIED TEMPERATURE RISE SAFETY FUNCTIONALITY CHECKED INRUSH AMPS OF COMPRESSOR UNIT RUNNING NORMALLY AT THIS TIME. DUAL RUN CAPACITOR WEAK ON OUT DOOR FAN SIDE BUT WITHIN MANUFACTURER'S SPECIFICATIONS.

Near S Sean Ct, Chandler, AZ 85286
Keith H.

Keith H.

PROBLEM: A/C UNITS WONT TURN OFF. SHUT POWER OFF AT BREAKER. DIAGNOSIS: WHEN I ARRIVED I TURNED THE POWER ON TO BOTH UNITS.. WHEN DOING SO THE ONLY UNIT IT TURN ON WITHOUT THE THERMOSTAT WAS THE NORTH UNIT. I WAS ABLE TO ISOLATE THE ISSUE TO THE MAIN CONTROL BOARD. I SWAPPED THE BOARDS AND THE ISSUE HAPPEND ON THE OPPOSITE UNIT. THE ISSUE IS THE BOARD HAS AN INTERNAL SHORT CAUSING THE SYSTEM TO RUN IN HEATING ENTIRELY. REPAIR: REPLACED THE MAIN CONTROL BOARD IN THE SOUTH UNIT. I WAS ABLE TO LEAVE THE GOOD BOARD IN THE NORTH UNIT. AFTER REPLACING THE BOARDS I WAS ABLE TO FIND THE THERMOSTATS PROGRAMED INCORRECTLY. THIS WAS WEATHER MASTERS DOING YESTERDAY. I WAS ABLE TO REPROGRAM THE AND NOW BOTH SYSTEMS ARE RUNNING JUST FINE IN COOLING AND HEATING..

Near N Delaware Ct, Chandler, AZ 85225
Keith H.

Keith H.

REPLACE RETURN AIR FILTERS. (32) 16X16X2 IN PLEATED FILTERS. WEATHER MASTERS WILL ALSO REPAIR THE 8 CONDENSATE LINES THAT WEATHER MASTERS CUT AND TAPED BACK TOGETHER. WEATHER MASTERS WILL CREDIT THE REPAIR COST OF THE 9TH UNIT DUE TO THEM HAVING A HANDY MAN FIXING THE 1 LINE. CREDIT $250.00

Near W Frye Rd, Chandler, AZ 85224
Stuart M.

Stuart M.

PROBLEM: UNIT BLOWING COLD AIR DIAGNOSIS: UNIT RUNNING IN DEFROST CYCLE DUE TO FREEZING COLD ATMOSPHERIC CONDITIONS. UNIT WAS SHUT OFF BY OWNER AND ICE MELTED NATURALLY DOWN COIL PRIOR TO SERVICE CALL. DURING TIME OF SERVICE CALL UNIT RUNNING NORMALLY IN HEATING

Near E Gleneagle Dr, Chandler, AZ 85249
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT FIRST CO. 18HX5-240 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING AT THIS TIME AMPS FOR ELECTRIC HEAT STRIPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /21 AMPS NO RECOMMENDED REPAIRS AT THIS TIME

Near W Ray Rd, Chandler, AZ 85224
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT FIRST CO. 18HX5-240 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING AT THIS TIME AMPS FOR ELECTRIC HEAT STRIPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /21 AMPS NO RECOMMENDED REPAIRS AT THIS TIME

Near W Ray Rd, Chandler, AZ 85224
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT FIRST CO. 18HX5-240 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING AT THIS TIME AMPS FOR ELECTRIC HEAT STRIPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /21 AMPS NO RECOMMENDED REPAIRS AT THIS TIME

Near W Ray Rd, Chandler, AZ 85224
Chris R.

Chris R.

PROBLEM NO HEAT FIRST CO 36HX0-70 T-STAT SET FOR E-HEAT AFTER SETTING T-STAT FOR HEAT THE HEAT CAME ON HOUSE IS HEATING AT THIS TIME DUE TO RAIN WE WOULD NEED TO RESCHEDULE IF FURTHER DIAGNOSTICS IS NEEDED FOR THE CONDENSER EXPLAINED THE OPERATION OF THE T-STAT TO THE TENANT

Near N Alma School Rd, Chandler, AZ 85224
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION 1 UNIT DAY AND NIGHT N8MPN050B12B2 A101143843 MFD 2010 DIAGNOSIS 10 MFD RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR HAS FAILED /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING WITHIN THE SPECIFIED TEMP RISE ACROSS THE HEAT EXCHANGER MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME TESTED ALL SAFTEY AND LIMIT SWITCHES /NO ISSUES AT THIS TIME REPAIRS REPLACED THE 10 MFD RUN CAPACITOR UNDER WARRANTY

Near S Callaway Dr, Chandler, AZ 85249
Keith H.

Keith H.

WEATHER MASTES PROPOSES TO: - REMOVE AND REPLACE THE OUTDOOR CONDENSER COIL. - REMOVE AND REPLACE LIQUIDE LINE FILTER DRIER. - PRESSURE TEST SYSTEM AND EVACUATE SYSTEM. - RECHARGE THE SYSTEM WITH 10LBS OF NEW R22 FREON. GOODMAN - SERIAL 0910182012 2-4-19 REMOVED AND REPLACED INDOOR EVAP COIL. RECHARGED THE SYSTEM WITH 9.5 LBS OF NEW R22 FREON. - AT THIS TIME THE SYSTEM IS RUNNING IN COOLING WITH A GOOD TEMPATURE SPLIT. NO OTHER REPAIRS NEEDED AT THIS TIME.

Near W Springfield Way, Chandler, AZ 85286
Nicole  P.

Nicole P.

REPLACED ALL AIR FILTERS ON ROOF TOP UNITS

Near W Chandler Blvd, Chandler, AZ 85225
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT CARRIER 58RAV095---16116 1396A13088 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING WITH A 50 DEGREE TEMPERATURE RISE ACROSS THE HEAT EXCHANGER /THIS IS WITHIN THE SPECIFIED RANGE FOR THIS FURNACE TESTED ALL SAFTEY AND LIMIT SWITCHES /NO ISSUES AT THIS TIME CHECKED MOTOR AMPS AND RUN CAPACITOR /ALL ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME THE UNIT IS SHOWING GENERAL WEAR DUE TO THE AGE AND USAGE NO RECOMMENDED REPAIRS AT THIS TIME

Near W Kesler Ln, Chandler, AZ 85226
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT DAY AND NIGHT FADED DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN HEATING MODE AND THE UNIT HEATING WITH A 53 DEGREE TEMPERATURE RISE ACROSS THE HEAT EXCHANGER /THIS IS WITHIN THE SPECIFIED RANGE FOR THE FURNACE TESTED ALL SAFTEY AND LIMIT SWITCHES /NO ISSUES AT THIS TIME MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME

Near N Bradley Dr, Chandler, AZ 85226
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS TRANE DOWNSTAIRS TUD080C948K4 4034YLD1G MFD:1/2004 UPSTAIRS TUD080C960K4 4403J8F1G MFD:9/2004 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND AND BOTH UNITS ARE HEATING WITHIN THE SPECIFIED TEMP RISE ACROSS THE HEAT EXCHANGERS TESTED ALL SAFTEY AND LIMIT SWITCHES /NO ISSUES AT THIS TIME 15 AND 10 MFD RUN CAPACITOR FOR THE INDOOR BLOWER MOTORS HAVE FAILED /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTORS BLOWER MOTORS /WHEELS AND POSSIBLE THE EVAPORATOR COILS ARE DIRTY /DUE TO THE AGE OF THE UNITS WE DON'T RECOMMEND ANY COSTLY REPAIRS /HOME OWNER DECLINED TO PULL AND CLEAN THESE PARTS AT THIS TIME REPAIRS REPLACED 15 AND 10 MFD RUN CAPACITORS FOR THE INDOOR BLOWER MOTORS

Near S Nash Way, Chandler, AZ 85286
Keith H.

Keith H.

PERFORM 37 PT INSPECTION ON SPLIT GAS HEAT STRAIGHT COOL A/C ALSO ADDRESS ISSUES HOME INSPECTOR FOUND. 1- FLU PIPE CLEANCE 2- CONDENSATE ISSUE DUE TO RUSTY FURNACE 3- LEAKING AIR FROM SUPPLY PLENUM 4- INSULATION ON SUCTION LINE. 5- POOR TEMPATURE SPLIT IN COOLING. DIAGNOSIS: ISSUES 1-4 HAVE BEEN ADDRESS AND TAKEN CARE OF. ISSUE 5 IS CAUSED BECAUSE WHILE RUNNING IN COOLING THE OUTDOOR COMPRESSOR AND FREON PRESSURES ARE NOT CORRECT. WEATHER MASTERS PERFORMED AN ELECTRONIC LEAK SEARCH OF THE SYSTEM AND FOUND A FREON LEAK IN THE OUTDOOR CONDENSER COIL. THE OUTDOOR COIL WILL NEED TO BE REPLACED AND THE SYSTEM RECHARGED WITH NEW R22 FREON BEFOR THE UNIT WILL COOL CORRECTLY. TESTED THE FURANCE IN HEATING. VERIFIED SEQUENCE OF OPERATION . THE FURNACE AT THIS TIME IS WORKING FINE WITH NO ISSUES. ALL SAFTY CONTROLS AND TEMPATURE HIGH LIMITS ARE FUNCTIONING CORRECTLY. DUE TO THE ISSUE WITH THE OUTDOOR CONDENSER , WEATHER MASTERS IS UNABLE TO PERFORM A FULL COOLING INSPECTION AT T

Near W Springfield Way, Chandler, AZ 85286
Keith H.

Keith H.

WEATHER MASTERS PURPOSES TO REMOVE AND REPLACE OUTDOOR TXV. WILL RECOVER AND REUSE R-22 REFRIGERANT NOTE: WEATHER MASTERS WILL ADD ADDITIONAL R-22 IF UNIT IS LOW ON CHARGE AT $100.00 PER LB Repair. Replaced valve. System is now heating just fine. Weather masters recommends cleaning the indoor coil and outdoor coil. System needed 2lbs of r22 FREON after recovery.

Near S Galaxy Dr, Chandler, AZ 85226
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT TRANE AUD2C080B9V4VBA 142143PW1G DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT HEATING WITHIN ITS SPECIFIED TEMPERATURE ACROSS THE HEAT EXCHANGER MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS 4UF RUN CAPACITOR IS WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME ALL SAFTEY AND LIMIT SWITCHES ARE WORKING AT THIS TIME

Near N Bell Pl, Chandler, AZ 85225
Keith H.

Keith H.

PERFORM HEATING INSPECTION ON 2 SYSTEMS. UPSTAIRS UNIT- UNIT IS HEATING JUST FINE WITH NO ISSUES. TESTED SYSTEM HIGH LIMITS AND SAFTY CONTROLS. UNIT IS HEATING WITH A 30 DEG SPLIT. . DOWNSTAIRS- TESTED SYSTEM IN HEATING AND FOUND IT TO HAVE WATER IN INSIDE THE BLOWER COMPARTMENT. WEATHER MASTES WAS ABLE TO FIND THE WATER IS COMING FROM THE HEAT EXCHANGER COMPARTMENT. THE FURNACE IS A 90% AND DOES PRODUCE CONDENSATE. THE CONDENSATE IS LOCATED INSIDE THE HEAT EXCHANGER.THE SYSTEM HAS A CRACKED HEAT EXCHANGER. THIS IS VERY BAD AND UNSAFE DUE TO THE POSSIBLE CARBON MONOXIDE THAT CAN FILTER INTO THE LIVING SPACE. WEATHER MASTERS DISABLED THE FURNACE FROM BEING ABLE TO HEAT AND ALSO RECOMMENDS REPLACING THE 90 % FURNACE. THE SYSTEM IS 15 YRS OLD AND DUE TO THE AGE AND NATURE OF ISSUE. WEATHER MASTERS RECOMMENDS REPLACING THE ENTIRE SYSTEM.

Near E La Costa Dr, Chandler, AZ 85249
Keith H.

Keith H.

WO14983 PROBLEM: A/C UNIT BLOWING COLD IN THE MORNING DIAGNOSIS: THE SYSTEM IS A ROOFTOP PACKAGE HEAT PUMP. THE SYSTEM IS GOING INTO DEFROST IN THE MORNING AND THIS IS WHY THEY ARE FEELING COLD AIR. THE UNIT IS NEWER AND HAS NO ISSUES AT THIS TIME. VERFIED SEQUENCE OF OPPERATION . UNIT IS HEATING WITH A 28 DEG SPLIT. NO REPAIRS NEEDED AT THIS TIME.

Near N Nebraska St, Chandler, AZ 85225
Keith H.

Keith H.

PROBLEM: UNIT TURNING OFF AND TURNING ON WHILE RUNNING IN HEATING DIAGNOSIS: UNIT HAS A RESTRICTED OUTDOOR TXV THAT IS CAUSING THE LOW PRESSURE SWITCH TO TURN OFF THE COMPRESSOR AND OUTDOOR FAN MOTOR AND WILL TURN BACK ON AGAIN ONCE PRESSURES RISE. WEATHER MASTERS PURPOSES TO REMOVE AND REPLACE OUTDOOR TXV AND RECOVER AND REUSE EXISTING R-22 REFRIGERANT. IF AT THE TIME OF THE REPAIR IT IS DISCOVERED THAT THE UNIT IS UNDERCHARED WEATHER MASTERS WILL CHARGE THE UNIT WITH R-22 REFRIGERANT AT $100.00 PER LB WITH PERMISSION OF CUSTOMER.

Near S Galaxy Dr, Chandler, AZ 85226
Keith H.

Keith H.

PROBLEM: NO HEAT IN FRONT OFFICE UNIT. OLD RHEEM PACKAGE HEAT PUMP. UNIT HAS A FAILED OUTDOOR FAN MOTOR. MOTOR IS A 1/20 HP WITH .4AMP RATING,, MOTOR NEEDS TO BE SPECIAL ORDERED ONCE FOUND. 1/8/19 RETURNED FOR RECOMMENDED REPAIRS REMOVED AND REPLACED OUTDOOR FAN MOTOR REMOVED AND REPLACED RUN CAPACITOR FOR MOTOR TESTED UNIT IN HEATING VERIFIED UNIT IS HEATING NORMALLY AFTER REPAIRS WITH 98 DEGREE SUPPLY AIR

Near E Comstock Dr, Chandler, AZ 85225
Keith H.

Keith H.

PROBLEM: A/C BLOWING COLD THIS MORNING DIAGNOSIS: UNIT WAS IN DEFROST . . DURING THE DEFROST CYCLE THE SYSTEM WILL SWITCH FROM HEATING TO AIRCONDITIONING. THIS IS NORMAL OPPERATION AND WILL ACCURE MOSTLY IN THE EARLY MORNING OR MIDDLE NIGHT AT THE COLDEST OUTDOOR TEMP. UNIT IS 20-30 YR OLD 5 TON GOETTLE UNIT IS WORKING IN HEATING JUST FINE. . TIGHTEN ELECTRICAL CONNNECTIONS. INSPECTED CONTACTORS AND CONTROL BOARDS. UNIT CONTACTOR SHOWING HEAT STRESS BUT THE CONNECTIONS WERE LOOSE. CONTACTOR STILL HAS SOME LIFE. INSPECTED THE EVAP COOLER. THE PAD LOOKS FINE . THE BLOWER WHEEL AND WET SECTION LOOK FINE. THE COOLER STILL HAS A LOT OF LIFE LEFT . THE COOLER WILL NEED A WATER LINE RAN AND WEATHER MASTERS CAN DO THIS WITH OUR PLUMBING DEVISION..

Near N Evergreen St, Chandler, AZ 85225
Stuart M.

Stuart M.

PROBLEM: NO HEAT DIAGNOSIS: THE OUTDOOR FAN NOT RUNNING DUE TO A FAIL DUAL RUN CAPACITOR. THE DUAL RUN CAPACITOR WILL NEED REPLACED TO RESTORE FUNCTION TO THE UNIT. REPAIR: REPLACED THE 55-5 DUAL RUN CAPACITOR AND RETESTED THE UNIT.. AT THIS TIME THE HOMEOWNER WANTS TO DO A FULL INSPECTION OF THE SYSTEM DIAGNOSIS: THE UNIT IS RUNNING FINE NOW WITH NEW CAPACITORS. WEATHER MASTERS PERFORMED HEATING INSPECTION. TESTED FREON LEVELS. AMP DRAWS OF THE INDOOR, OUTDOOR AND COMPRESSOR MOTORS. HOSED OFF THE OUTDOOR COIL. THE OUTDOOR COIL WAS REALLY DIRTY AND NEEDED HOSED OUT. TESTED THE HEAT PUMP DEFROST CYCLE. AT THIS TIME THE UNIT DEFROST WORKS PERFECTLY WITH NO ISSUES. WEATHER MASTERS RECOMMENDS OUR PMP MAINTENANCE PROGRAM TO ENSURE FUTURE INSPECTIONS AND SAVE ON FUTURE REPAIRS.

Near N Layman Ct, Chandler, AZ 85225
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE

Near W Frye Rd, Chandler, AZ 85224