PROBLEM: SYSTEM NOT COOLING. ONLY FAN TURNS ON. DIAGNOSIS: BAD RUN CAPACITOR. COMPLETELY DEAD. REPAIR: REPLACE 35 MFD RUN CAPACITOR SYSTEM IS NOW RUNNING AS IT SHOULD

Near W Corrine Dr, El Mirage, AZ 85335
Stuart M.

Stuart M.

WO#16452 UPSTAIRS UNIT- FULL PACKAGE UNIT CLEANING OF INDOOR AND OUTDOOR COILS. REMOVE AND REPLACE CONDENSER FAN MOTOR AND BLADE WITH NEW MARC ECM 1/8-1/3 HP AND NEW EOM FACTORY CONDENSER FAN BLADE. DOWNSTAIRS UNIT- FULL PACKAGE UNIT CLEANING OF INDOOR AND OUTDOOR COILS. REMOVE AND REPLACE INDOOR BLOWER WHEEL. NOTE- UNITS ARE 19 YRS OLD AND SHOWING HEAVY WEAR DUE TO AGE AND LACK OF MAINTENANCE. WEATHER MASTERS MAKES NO GUARANTEE OF EQUIPMENT FUCTION EXECEPT FOR PARTS REPLACED. ALL UNITS WORKING RUNNING NORMALLY AT THIS TIME. WEATHER MASTERS DOES NOT GUARUNTEE SYSTEM OPERATION DUE TOAGE AND LACK OF MAINTENCE

Near W Crocus Dr, El Mirage, AZ 85335
Keith H.

Keith H.

WO16481 PROVIDE ESTIMATE FOR UNIT REPLACMENT.

Near W Crocus Dr, El Mirage, AZ 85335
Keith H.

Keith H.

WO16316 PROBLEM: UNIT IS MAKING A LOUD RATTLE UPSTAIRS. UNITS ARE COOLING. DIAGNOSIS: TWO STORY HOME HAS TWO UNITS. UPSTAIRS UNIT- GOODMAN 2000 3 TON HEAT PUMP. UNIT IS SHOWING HEAVY WEAR FROM A LACK OF MAINTENANCE. WEATHER MASTERS RECOMMENDS THIS UNIT TO HAVE A FULL CLEANING. THIS UNIS DOES HAVE A SMALL RATTLE AND APPEARS TO BE COMING FROM THE INDOOR BLOWER WHEEL. THE WHEEL IS VERY DIRTY/ RUSTY AND OUT OF BALLANCE. WEATHER MASTERTS RECOMMENDS REPLACING BLOWER WHEEL. DOWNSTAIRS UNIT- GOOD MAN 2000 3.5 TON. UNIT IS SHOWING HEAVY WEAR DUE TO A LACK OF MAINTENANCE. WEATHER MASTERS RECOMMENDS THIS UNIT TO HAVE A FULL CLEANING. THIS UNIT IS THE PRIMARY SOURCE OF THE RATTLE. THE OUTDOOR FAN MOTOR BEARINGS ARE SHOT AND THE FAN BLADE IS OUT OF BALLANCE CAUSING THE RATTLE THRU OUT THE UNIT AND THRU THE ROOF. WEATHER MASTERS RECOMMENDS REPLACING THE OUTDOOR FAN MOTOR AND FAN BLADE. NOTE- EQUIPMENT IS 19 YRS OLD AND SHOWING HEAVY WEAR DUE TO AGE AND LACK OF MAINTENANCE. WEATHER

Near W Crocus Dr, El Mirage, AZ 85335
Keith H.

Keith H.

WO-16355 PROBLEM: TENTANT STATES UNIT NOT COOLING AND WONT TURN ON THE FAN. DIAGNOSIS: WHEN ARRIVED TO THE HOME WEATHER MASTERS TURNED ON THE SYSTEM. WEATHER MASTERS FOUND THE SYSTEM TO TURN ON FINE. WEATHER MASTERS PERFORMED AN INSPECTION OF THE SYSTEM AND FOUND THE OUTDOOR COIL TO BE VERY DIRTY. WEATHER MASTERS FOUND THE INDOOR COIL TO BE DIRTY. WEATHER MASTERS FOUND ICE ON THE INDOOR COIL INDICATING THE DIRTY COIL AND POSSIBLE DIRTY AIR FILTERS RECENTLY. DURING THE INSPECTION THE SYSTEM WAS TURNED ON AND OFF AND AT ONE POINT DID NOT TURN BACK OK. WEATHER MASTERS NEEDED TO REPLACE THE COMPRESSOR START ASSIT FORCE THE COMPRESSOR RUNNING . WEATHER MASTERS RAN THE SYSTEM FOR MORE THEN AN HOUR. WEATHER MASTERS CLEANEEED THE OUTDOOR COIL TO ACHEIVE BETTER COOLING. AFTER THE CONDENER COIL WAS CLEANED THE SYSTEM RAN FOR AN OTHER 30 MIN BEFORE SHUTTING DOWN AGAIN. FINAL DIAGNOSIS; BECAUSE OF A DIRTY INDOOR COIL AND A DIRTY OUTDOOR COIL THE COMPRESOR HAS INTERNAL DAMAGE RESU

Near W Paradise Dr, El Mirage, AZ 85335