Review of Weather Masters, Inc.

I like that they use a hose to clean the coils and drain tube since there is a lot of dust build up in Arizona.


Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT DAY AND NIGHT N4H348AKF200 E132709708 CONDENSER FAN MOTOR IS INTERNALLY DAMAGED /DUAL RUN CAPACITOR HAS FAILED /RECOMMEND REPLACING THE MOTOR UNDER WARRANTY VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE COIL MOTOR AMPS FOR THE CONDENSER FAN MOTOR ARE HIGH DUE TO A FAILED RUN CAPACITOR ALL OTHER MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN REPAIRS REPLACED 1/4 HP 1110 RPM CONDENSER FAN MOTOR AND 70/5 DUAL RUN CAPACITOR

Near N Rica Vida Way, Fountain Hills, AZ 85268
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT DAY AND NIGHT PHJ424000KTP0A1 C163196844 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 PLUS DEGREE TEMPERATURE SPLIT ACROSS THE COIL 40/5 DUAL RUN CAPACITOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED NEXT VISIT ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near E Palisades Blvd, Fountain Hills, AZ 85268
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION @2 #41and#42 COMFORTMAKER/ICP #42:PHAD24N1K5 LO14080407 #41 FADED PHAD30 DIAGNOSIS #41 CONDENSER FAN MOTOR AND BLADE HAVE FAILED /NEED TO REPLACE BEFORE WE CAN FINISH THE INSPECTION UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE REPAIRS REPLACED 1/4 HP 825 RPM CONDENSER FAN MOTOR REPLACED 45/5 DUAL RUN CAPACITOR TIGHTENED ALL ELECTRICAL CONNECTIONS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS THE EVAPORATOR COIL TESTED DEFROST CYCLE /NO ISSUES AT THIS TIME MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME DIAGNOSIS #42 UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL SOON RUN CAPACITORS 40/3 SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME VERIFIED SEQUENCE OF OPERATION IN HEATING MODE AND THE UNIT IS HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS THE EVAPORATOR COIL MOTOR AMPS ARE WITHIN MANUFACTURE SPE

Near E Palisades Blvd, Fountain Hills, AZ 85268