Gilbert, AZ — Plumbing, Heating and Air Conditioning Service

Weather Masters, Inc. provides plumbing, heating  & Air Conditioning repair and installation services in Gilbert, AZ and surrounding areas.

Check out what some of our customers are saying about Weather Masters, Inc.

Local Reviews
for Gilbert, AZ

Weather Masters, Inc. Rated 5.0 out of 5 stars based on 11 customer reviews

Map of Gilbert, AZ

Great Service




Review of Weather Masters, Inc.


Map of Gilbert, AZ

Delightful!




Review of Weather Masters, Inc.

Your rep. was very knowledgeable, efficient, polite and delightful to wark with. Thanx!


Map of Gilbert, AZ

Great service




Review of Weather Masters, Inc.

Quick to schedule and Jason was very conscientious.


Map of Gilbert, AZ

Tech was amazing




Review of Weather Masters, Inc.

Keith was so extremely helpful when giving me a second opinion. He was informative and helpful and explained everything to me because I am a new home owner. I felt like he was being completely honest with me instead of trying to upsell me or tell me there were problems so I’d purchase a new unit. He was professional and thorough and even drew out pictures to help me understand the issue. I’d recommend this company and when I do buy a new unit I’ll happily go through them.


Map of Gilbert, AZ

Great




Review of Weather Masters, Inc.

Chris was great, very happy with the service and looking forward to having him continue servicing our a/c needs.


Map of Gilbert, AZ

Great Service, Great Technician




Review of Weather Masters, Inc.

I have used WeatherMasters for at least 25 years. I have never been disappointed and always appreciate their professionalism and quick. They feel more like family.


Map of Gilbert, AZ

Jason is great




Review of Weather Masters, Inc.

Excellent communication and explanation


Map of Gilbert, AZ

Great Service!




Review of Weather Masters, Inc.

Jason was very friendly and knowledgeable! I always know I’m in good hands with Weather Masters. There’s never any up-selling, just honest, hard work. It’s great working with a company you can trust. I also love their maintenance program. I never have to remember to schedule an appointment for a tune-up with this program. Every 6 months, I receive a reminder.


Map of Gilbert, AZ

Great tech




Review of Weather Masters, Inc.

Tech did a good job


Map of Gilbert, AZ

Good Service




Review of Weather Masters, Inc.


A/C Proposal




Review of Weather Masters, Inc.

Chris was on time and very informative. My A/C is pretty old and I am trying to determine how much I need to have to replace my unit.


Jason G.

Jason G.

Summer inspection

Near E Bruce Ave, Gilbert, AZ 85234
Stuart M.

Stuart M.

PROBLEM: DOWNSTAIRS UNIT NOT COOLING DIAGNOSIS: TSTAT NOT CALLING FOR COOLING DUE TO LOW BATTERY. REPLACED BATTERY AND UNIT RAN NORMALLY IN COOLING.

Near S Marina Dr, Gilbert, AZ 85233
Stuart M.

Stuart M.

PROBLEM: UNITS IN MAIN ROOM NOT COOLING DIAGNOSIS: UNITS WERE SHUT OFF AT OUT DOOR DISCONNECT NOT ALLOWING COMPRESSORS OR OUTDOOR FAN MOTORS TO TURN ON. DISCONNECT WAS SWITCHED ON AND BOTH UNITS RUNNING IN COOLING

Near Spectrum Way, Gilbert, AZ 85295
Stuart M.

Stuart M.

PROBLEM: UPSTAIRS UNIT NOT COOLING DIAGNOSIS: DUAL 60/5 MF RUN CAPACITOR FAILED CAUSING COMPRESSOR NOT TO TURN ON. COMPONENT WAS REPLACED AND UNIT RUNNING IN COOLING. DUE TO COMPRESSOR OPERATING WITH FAILED CAPACITOR IT MAY HAVE SUSTAINED PERMANENT INTERNAL DAMAGE. UPSTAIRS UNIT HAS BROKEN HANDLE ON DISCONNECT. DISCONNECT MUST BE OPENED BY PRYING.

Near E Devonshire Ct, Gilbert, AZ 85297
Chris R.

Chris R.

1/4" floats 39-27-8 pads A-57 belt $601

Near W Harvard Ave, Gilbert, AZ 85233
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON TWO PACKAGE GAS AC UNITS CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERIFIED TEMP SPLIT ACROSS COILS CHECKED IN RUSH AMPS OF COMPRESSORS TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNITS BOTH UNITS RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near S Marina Dr, Gilbert, AZ 85233
Keith H.

Keith H.

RATTLE IN THE FURNACE. I WAS ABLE TO FIND THE ISSUE AS TO WHY THE FURNACE WAS RATTTLING. I WAS ABLE TO ADJUST THE HEAT EXCHANGER TO ELIMINATE THE NOISE. ALSO THE RATTLE THE HOMEOWNER WAS HEARING DOWNSTAIRS WAS THE CEILING REGISTER. I WAS ABLE TO ADJUST THE REGISTER TO ELIMINATE THE NOISE. THE SYSTEM IS RUNNING QUIET NOW .

Near S Kolb St, Gilbert, AZ 85297
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON TWO SPLIT GAS AC UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERIFIED TEMP SPLIT ACROSS COILS CLEANED OUTDOOR COILS TIGHTENED ELECTRICAL CONNECTIONS CHECKED IN RUSH AMPS OF COMPRESSORS INSPECTED CONDITION OF UNITS BOTH UNITS RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS INSTALLATION OF START ASSIST CAPACITORS TO HELP PROLONG LIFE OF COMPRESSORS. WEATHER MASTERS ALSO RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near E Horseshoe Ave, Gilbert, AZ 85296
Chris R.

Chris R.

CHEMICALLY CLEAN EVAPORATOR COIL IN PLACE CLEANED EVAPORATOR COIL

Near N Cliffside Dr, Gilbert, AZ 85234
Keith H.

Keith H.

PROVIDE SECOND OPINION FOR CONDENSATE LEAK AND OVERALL CONDTION OF A/C DIAGNOSIS: AT THIS TIME THE SYSTEM IS NO LONGER LEAKING CONDENSATE. IT DOES APPEAR THE SYSTEM HAD A CLOGGED CONDENSATE LINE. WATER WAS MORE THEN LIKLY OVER FLOWING THE PRIMARY PAN AND BEING BLOWN INTO THE SUPPLY PLENUM. DUE TO THE WAY THE EQUIPMENT WAS INSTALLED THE SECONDARY DRAIN PAN WILL NOT CATCH DRIPING WATER FROM THE PLENUMS. AFTER SPEAKING WITH BETH ABOUT THE OVER ALL CONDITION OF THE SYSTEM AND HOW UNHEALTHY THE COMPRESSOR SOUNDS. WEATHER MASTERS RECOMMENDS REPLACING THE A/C SYSTEM WITH A MORE RELIABLE AND MORE EFFICIENT SYSTEM. BETH AND I SPOKE ABOUT THE OPTION OF REPLACING THE STRAIGHT COOL GAS FURNACE WITH A NEW HEAT PUMP SYSTEM.

Near S Bridal Vail Dr, Gilbert, AZ 85297
Stuart M.

Stuart M.

PERFORMED PMP INPECTION ON 2 SPLIT GAS AC UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERFIED TEMP SPLITS ACROSS COILS CLEANED OUTDOOR COILS TIGHTENED ELECTRICAL CONNECTIONS TESTED INRUSH AMPS OF COMPRESSORS INSPECTED CONDITION OF UNITS UNITS RUNNING IN COOLING AT TIME OF INSPECTION. SOUTH UNIT COMPRESSOR PULLING HIGH IN RUSH AMPS AND MAKING MINOR NOISE ON START-UP. START ASSIST CAPACITOR WAS INSTALLED AT TIME OF INSPECTION AND BROUGHT IN RUSH AMPS DOWN TO 22 FROM 79. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near S Boulder Ct, Gilbert, AZ 85295
Chris R.

Chris R.

MIDEA 36CN1-M14C C704513920417A221400006 FURN GMTH070-4A 0211629447 COIL HT-4248 03037048301 R22

Near E Meadowview Dr, Gilbert, AZ 85298
Chris R.

Chris R.

PROBLEM NO COOL UNIT #3 50HJQ006---521HY 0707G10620 DIAGNOSIS INTERMITTENT LOW VOLT SHORT PREFORMED LOW VOLT SHORT TRACE /I WAS ABLE TO STOP THE SHORT CAN'T PIN POINT WHAT PORTION OF THE WIRE IS SHORTING AT THIS TIME/WE WILL NEED TO REWIRED THE THE CIRCUIT IF IT HAPPENS AGAIN

Near Mercy Rd, Gilbert, AZ 85297
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION GOODMAN SSZ140421AJ 1503006902 DIAGNOSIS DIRTY EVAPORATOR COIL /THIS WILL LIQUEFY THE REFRIGERANT AND CAUSE INTERNAL DAMAGE TO THE COMPRESSOR /RECOMMEND CHEMICALLY CLEANING THE EVAPORATOR COIL IN PLACE 45/5 DUAL RUN CAPACITOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME UNIT COOLING BUT WE CAN'T VERIFY CHARGE UNTIL WE CLEAN THE COIL TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near N Cliffside Dr, Gilbert, AZ 85234
Stuart M.

Stuart M.

WEATHER MASTERS CAME TO FOLLOW UP ON THE NEW SYSTEM AND MAKE SURE THERE ARE NO ISSUES. THE CHARGE ON THE SYSTEM WAS CHECKED. THE CHARGE IS OPTIMAL FOR THE UNIT. SUPER HEAT OF 13 AND SUBCOOL OF 12. THE SYSTEM IS OPERATING NORMALLY AT THIS TIME.

Near E Caleb Way, Gilbert, AZ 85234
Stuart M.

Stuart M.

WO 16959 PROBLEM: SYSTEM NOT BLOWING COLD AIR DIAGNOSIS: UNIT IS LOW ON CHARGE DUE TO LEAK FOUND ON EVAP COIL RECOMMENDED REPAIR: REPLACE EVAP COIL AND REFRIGERANT

Near E Meadowview Dr, Gilbert, AZ 85298
Stuart M.

Stuart M.

PROBLEM: SYSTEM NOT COOLING AND OUTSIDE UNIT MAKING LOUD SOUND DIAGNOSIS: UNIT IS COMPLETELY OUT OF REFRIGERANT. A LEAK WAS FOUND IN EVAP COIL RECOMMEND REPAIR: EVAP COIL REPLACMENT AND PUT 410A IN SYSTEM.

Near E Franklin Ave, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS NORTH DAY AND NIGHT PHJ442000KTPOA1 C171999507 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL AND OVER HEATING /MAY BE FAILING DURING HEAT OF THE DAY/SHAFT AND BEARING DAMAGE/WE WILL REPLACE MOTOR UNDER WARRANTY /LABOR COST ONLY COMPRESSOR MAY HAVE TAKEN INTERNAL DAMAGE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE COIL NO OTHER ISSUES AT THIS TIME COMPRESSOR AND INDOOR BLOWER MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME RHEEM #FADED RUN CAPACITOR FOR THE CONDENSER AND INDOOR BLOWER HAVE FAILED /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTORS RECOMMEND REPLACING BOTH CAPS DUE TO AGE AND CONDITION OF THIS UNIT WE DON'T RECOMMEND ANY COSTLY REPAIRS THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL AMPS FOR ALL MOTORS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME REPAIRS REPLACE OEM CONDENSER FAN MOTOR UNDER WARRANTY /LABOR ONLY TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near S Lindsay Rd, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM 37PT INSPECTION NORDYNE FT4BF-060KA FTD090702661 DIAGNOSIS WEAK 80 MFD RUN CAPACITOR FOR THE COMPRESSOR /THIS WILL ALLOW INTERNAL DAMAGE TO THE COMPRESSOR /RECOMMEND REPLACING THE CAP SOON IMPROPERLY PIPED CONDENSATE DRAIN/SAFTEY FLOAT SWITCH IS INSTALLED ON THE PRIMARY SIDE OF THE COIL AND THE SECONDARY DRAIN IS NOT PLUGGED /THIS WILL ALLOW WATER TO OVER FLOW INTO THE SECONDARY DRAIN PAN VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL REFRIGERANT CHARGE IS OK AT THIS TIME ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN REPAIRS REPLACED 80 MFD RUN CAPACITOR UNDER WARRANTY REPAIRED DRAIN UNDER WORKMANSHIP WARRANTY

Near E Austin Dr, Gilbert, AZ 85296
Stuart M.

Stuart M.

Wo#16262 PROBLEM 37 POINT INSPECTION WEATHER MASTERS PERFORMED THE FOLLOWING: -TIGHTENED ELECTRICAL CONNECTIONS -CHECKED DISCONNECT. DISCONNECT SHOWING WEAR -AMPS ON INDOOR AND OUTDOOR FAN ARE OPTIMAL -CAPACITOR IS WITHIN RANGE -SUPERHEAT OF 15 PRESSURES AND FREON LEVELS ARE GOOD -TEMPERATURE SPLIT IS GOOD AT 18 DEGREES -THERMOSTAT WORKING -SYSTEM IS MISSING FILTER DRIERS AND INSULATION ON OUTSIDE SUCTION LINE -LARGE DENT IN CONDENSER. IS WORKING AS SHOULD THOUGH -FURNACE IS WORKING AS IT SHOULD AT THIS TIME THE SYSTEM IS OPERATING NORMALLY

Near E Redfield Ct, Gilbert, AZ 85234
Stuart M.

Stuart M.

PROBLEM: THERMOSTAT NOT PROPERLY DISPLAYING CORRECT AMBIENT TEMPERTATURE THEREFORE UNIT STAYED ON LONGER THAN NECCESARY DIAGNOSIS: THERMOSTAT IS VERY OLD AND WEATHER MASTERS RECOMMENDS REPLACEMENT REPAIR: WEATHER MASTERS REPLACED 20 YEAR OLD LUX THERMOSTAT WITH A HONEYWELL 5000. UNIT IS NOW OPERATING NORMALLY

Near W Orange Dr, Gilbert, AZ 85233
Chris R.

Chris R.

CHECK CHARGE

Near S 179th Way, Gilbert, AZ 85298
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION DAY AND NIGHT PHD342000K000C1 C111558697 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL /THIS IS WITHIN MANUFACTURE SPECIFICATIONS THE 45/5 DUAL RUN CAPACITOR IS SHOWING WEAR /WE RECOMMEND REPLACING AT THE WINTER INSPECTION /THIS WILL HELP EXTEND THE LIFE OF THE MOTORS NO OTHER ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN SEE ATTACHED FOR RECOMMENDATIONS

Near E Tremaine Ave, Gilbert, AZ 85234
Chris R.

Chris R.

PROBLEM CHECK CHARGE

Near S Griswold St, Gilbert, AZ 85297
Chris R.

Chris R.

PROBLEM SRP INSPECTION DAY AND NIGHT N4H442GKG101 E171209002 DIAGNOSIS UNIT IS A LITTLE LOW ON REFRIGERANT CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL PREMATURELY CONDENSER FAN MOTOR IS AFTER MARKET W/M DID THIS PER RON FROM AIRECOLD DUE TO NOISE ISSUES FROM THE OEM MOTOR 12.5 RUN CAPACITOR FOR THE THIS MOTOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED NEXT VISIT O OTHER ISSUES AT THIS TIME REPAIRS ADDED 1LBS OF REFRIGERANT TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near E Lakeside Dr, Gilbert, AZ 85234
Keith H.

Keith H.

PROBLEM: NORTH BUILDING UNIT E16 NOT WORKING PROPERLY. DIAGNOSIS: AT FIRST THE AIR HANDLER APPEARED TO HAVE A FAULTY TEMPATURE SENSOR . BEFORE REPLACING THE SENSOR I PERFORM A FULL SYSTEM 8 TEST. I FOUND THE ENTIRE SYSTEM TO BE LOW ON R410A FREON. AT THIS TIME I CHECKED 5,6,7,8 SYSTEM 5 ALSO APPEARS TO BE VERY LOW ON FREON AT THIS TIME. I SPOKE WITH DOUG AND THEY WILL HAVE THE SPECIAL COMPANY THAT FINDS LEAKS DO A LEAK SEARCH OF THESE TWO SYSTEMS. DOUG WILL LET ME KNOW WHAT THEY FIND AND WHAT THEY WOULD LIKE US TO DO .

Near N Lindsay Rd, Gilbert, AZ 85234
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE

Near Mercy Rd, Gilbert, AZ 85297
Keith H.

Keith H.

RETURN TO REPLACE 1.5 POLE CONTACTOR AND 10MF RUN CAPACITOR FOR OUTDOOR FAN. WEATHER MASTERS REPLACED CONTACTOR AND CAPCITOR. UNIT IS COOLING GREAT WITH NO OTHER ISSUES AT THIS TIME. PARTS UNDER WARRANTY. LABOR ONLY

Near S Jacqueline Way, Gilbert, AZ 85298
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON ONE SPLIT GAS AC UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COIL CLEANED OUTDOOR COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. UNIT IS SHOWING NORMAL WEAR FOR AGE BUT FUNCTIONING PROPERLY. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near W Shannon St, Gilbert, AZ 85233
Chris R.

Chris R.

PROBLEM NO COOL GOODMAN GSX160481FA 1403220230 DIAGNOSIS 1.5 COMPRESSOR CONTACTOR IS BURNED AND PITTED /FAILING IN THE CLOSED POSITION CONDENSER FAN MOTOR HAS BEARING /INTERNAL DAMAGE /MAY FAIL PREMATURELY /RECOMMEND REPLACING THE MOTOR RECOMMENDATIONS MAINTENANCE ON THE SYSTEM TO HELP DETERMINE OVER CONDITION OF THE UNIT REPLACE 1/4 HP 830 RPM CONDENSER FAN MOTOR ATTACHED IS A ESTIMATE FOR RECOMMENDATIONS REPAIRS REPLACED 1.5 COMPRESSOR CONTACTOR VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near E Muirfield St, Gilbert, AZ 85298
Keith H.

Keith H.

INSTALL NEW HONEYWELL 800O THERMOSTAT W/ 3 REMOTE WIRELESS SENSORS.

Near N Lindsay Rd, Gilbert, AZ 85234
Keith H.

Keith H.

SRP 37 POINT INSPECTION DIAGNOSIS: WEATHER MASTERS PERFORMED A 37 POINT INSPECTION ON A STRAIGHT COOL SPLIT SYSTEM. UNIT I PERFORMING NORMALLY AT THIS TIME. DURING THE INSPECTION, THE CONTACTOR ON THE OUTSIDE UNIT WAS FOUND TO HAVE A BROKEN HOUSING. THE CONTACTOR IS STILL FUNCTIONING. THE CAPACITOR FOR THE OUTSIDE UNIT IS FOUND TO BE OUTSIDE ITS MINIMAL TOLERANCE. WEATHER MASTERS RECOMMENDS REPLACING CONTACTOR OTHERWISE DURING MAINTENCE, WEATHER MASTERS CANNOT ENSURE PROPERLY TIGHT CONNECTIONS. THE CAPACITOR IS ALSO RECOMMENDED FOR REPLACEMENT. DURING INSPECTION, WEATHER MASTERS TIGHTENED ELETRICAL CONNECTIONS, HOSED OFF OUTDOOR COIL, AND FLUSHED THE CONDENSATE DRAIN LINE. AT THIS TIME, EQUIPMENT IS OPERATING NORMAL WITH NO MAJOR REPAIRS NECCESARY.

Near S Jacqueline Way, Gilbert, AZ 85298
Chris R.

Chris R.

PROBLEM NO COOL /UNIT #1/STORAGE RM CARRIER 50HJQ006---521HY 0707G10621 DIAGNOSIS FAN RELAY FAILED /INDOOR COIL IS ICED OVER/THIS WILL CAUSE PERMANENT INTERNAL DAMAGE TO THE COMPRESSOR REPAIRS REPLACED 24 VOLT FAN RELAY VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME THE UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE /RECOMMEND REPLACING THE UNIT IF COSTLY REPAIRS ARE NEEDED

Near Mercy Rd, Gilbert, AZ 85297
Robert T.

Robert T.

WEATHER MASTERS PROPOSES TO: - REMOVE AND HAUL AWAY EXISTING 5 TON A/C GAS FURNACE - INSTALL NEW 5 TON DAY AND NIGHT 14 SEER STRAIGHT COOL A/C WITH NEW GAS FURANCE. - INSTALL NEW EMERGENCY CONDENSATE DRAIN PAN. - INSTALL NEW CONDENSATE FLOAT SAFTY SWITCH. - INSTALL NEW FLEXABLE FLU PIPE. - INSTALL NEW FLEXABLE GAS LINE AND BALL VALVE. - INSTALL NEW SERVICE DISCONNECT AND ELECTRICAL WHIP. - INSTALL NEW HONEYWELL 8000 WIFI STAT. - INSTALL 2 NEW 20X20 BAR TYPE FILTER GRILLS. PERFORM SYSTEM TEST AND SET UP. WARRANTY- 10 YR PARTS 10 YR COMPRESSOR , 1 YR LABOR. OPTIONAL LABOR WARRANTY FOR $1013.00 NOTE: WEATHER MASTERS IS NOT RESPONSIBLE FOR DRYWALL/PAINT REPAIR DUE TO ATTIC ACCESS ENLARGMENT FOR EQUIPMENT CHANGE OUT.

Near S Kolb St, Gilbert, AZ 85297
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT /1st VISIT CARRIER 24ABC642A0030010 0314E11456 DIAGNOSIS UNIT SHOWING GENERAL WEAR DUE TO AGE AND USAGE 45/5 AND 7.5 RUN CAPACITORS ARE SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near E Ficus Way, Gilbert, AZ 85298
Keith H.

Keith H.

PROBLEM : NO COOL ON UPSTAIRS UNIT. DIAGNOSIS: THE OUTDOOR UNIT HAS A FAILED COMPRESSOR DUE TO A DIRTY INDOOR COIL. THE COMPRESSOR HAS MECHANICALY FAILED AND MAY HAVE CONTAMINATED R-22 FREON WITH METAL DEBRIS. THE COMPRESSOR FAILURE CAUSED THE CAPACITORS TO FAIL AND ELECTRICAL WIRES TO BURN UP. THE CONDENSER FAN MOTOR SHOWING HEAVY WEAR. OPTIONAL REPAIR- 1- REMOVE AND REPLACE UNIT COMPRESSOR. REMOVE AND CHEMICAL CLEAN THE INDOOR COIL. INSTALL NEW COMPRESSOR RUN CAPACITOR AND LIQUID LINE FILTER DRIER, FLUSH FREON LINES. EVACUATE SYSTEM AND RECHARGE WITH NEW FREON. REMOVE AND REPLACE CONDENSER FAN MOTOR WITH MARS ECM MOTOR. 2- REPLACE ENTIRE SYSTEM WITH A NEW 5 TON A/C WITH GAS FURNACE.

Near S Kolb St, Gilbert, AZ 85297
Noel@acdudes.com

Noel@acdudes.com

WEATHER MASTERS PROPOSES: * REMOVE AND HAUL AWAY EXISTING 5 TON SPLIT GAS A/C SYSTEM * INSTALL NEW DAY & NIGHT 14 SEER 5 TON SINGLE STAGE A/C WITH NEW 110K BTU GAS FURNACE. * INSTALL NEW FUSED service DISCONNECT AND ELECTRICAL WHIP FOR OUTSIDE CONDENSER * INSTALL NEW HONEYWELL 8000 SINGLE STAGE REDLINK THERMOSTAT * INSTALL NEW 20X30 and 20x20 bar type filter grill * INSTALL NEW PLENUMS * INSTALL NEW FLU PIPE * RE-ATTACH GAS FURNACE AND CASE COIL TO EXISTING ELECTRICAL, FREON, GAS AND CONDENSTATE LINES. *** IN ODER TO CHANGE OUT THE EQUIPMENT IN THE ATTIC, SOMTIMES THE ACCESS HOLE NEEDS TO BE ENLARGED. IF THE ACCESS HOLE NEEDS ENLARGED WEATHER MASTERS IS NOT RESPONSIBLE FOR DRYWALL REPAIR NEEDED AFTER THE FACT. WARRANTY- 10 YR PARTS, 10 YR COMPRESSOR, 1 YR LABOR PRICE INCLUDES PARTS, LABOR AND MATERAL TO COMPLETE THE JOB.

Near S Griswold St, Gilbert, AZ 85297
Chris R.

Chris R.

PROBLEM SRP INSPECTION @2 KITCHEN /LENNOX 14ACX-060-230 1912C27723 DIAGNOSIS 40 MFD FOR THE INDOOR BLOWER MOTOR HAS FAILED /MOTOR HAS TAKEN PERMANENT INTERNAL DAMAGE RECOMMEND REPLACING THE CAP NO OTHER ISSUES AT THIS TIME GUEST/LENNOX 14ACX-18-230-12 1912F25278 DIAGNOSIS 30/5 DUAL RUN CAPACITOR FOR THE CONDENSER HAS FAILED /THE COMPRESSOR AND CONDENSER FAN MOTOR HAVE TAKEN PERMANENT INTERNAL DAMAGE /5 MFD RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR HAS FAILED /RECOMMEND REPLACING BOTH CAPS NO OTHER ISSUES AT THIS TIME BOTH UNITS ARE COOLING WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME REPAIRS REPLACED 30/5DUAL RUN CAPACITOR 40 MFD 5MFD TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COILS FLUSHED DRAINS USED 1ST VISIT 3 LEFT

Near E Furness Dr, Gilbert, AZ 85297
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION IN SPLIT GAS A/C. CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS FOR PERFORMANCE TO BE WITHIN MANUFACTURES RATING VERIFIED TEMP SPLIT ACROSS COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT HAS OUTDOOR FAN MOTOR THAT IS PULLING MAXIMUM AMPS AT 1.4 MOTOR ALSO HAS WORN OUT BEARINGS AND BECAME EXCESSIVELY HOT DURING OPERATION. RESIDENT DOES NOT WISH TO REPLACE UNTIL FAILURE. UNIT RUNNING IN COOLING AT TIME OF INSPECTION

Near E Trigger Way, Gilbert, AZ 85297
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON 2 SPLIT HEAT PUMP UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS FOR PERFORMANCE WITHIN MANUFACTURES RATING VERIFIED TEMP SPLIT TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNITS NORTH OUTDOOR UNIT HAD LOW 5MF RUN CAPACITOR CAUSING OFM TO PULL MAXIMUM AMPS (1.5). CAPACITOR WAS CHANGED AT TIME OF INSPECTION AND MOTOR NOW PULLING 1.3 AMPS. UNITS BOTH RUNNING NORMALLY IN COOLING UPON COMPLETION OF INSPECTION.

Near E Toledo St, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM NO COOL 16290 GOODMAN CK42-1C 9704146688 DIAGNOSIS LOW VOLT SHORT AT T-STAT REPLACED T-STAT /HONEYWELL 6000 PROGRAMMABLE UNIT SHOWING HEAVY WEAR DUE TO AGE AND USAGE /BUT COOLING AT THIS TIME RECOMMEND REPLACING THE UNIT

Near S Roanoke St, Gilbert, AZ 85296
Stuart M.

Stuart M.

PROBLEM UPSTAIRS UNIT NOT COOLING DIAGNOSIS: EVAPORATOR COIL LEAKING R22 REFRIGERANT. COIL MUST BE REMOVED AND REPLACED AND UNIT CHARGED WITH R22 REFRIGERANT.

Near S Griswold St, Gilbert, AZ 85297
Chris R.

Chris R.

7.5 MFD RUN CAPACITOR @2 15 MFD RUN CAPACITOR @2 CHEMICALLY CLEAN EVAPORATOR COIL IN PLACE @2 CHEMICALLY CLEAN CONDENSER COIL @2 PULL AND CLEAN BLOWER WHEEL@2 REPLACE 20-25-1 FILTERS @4 AFTER FURTHER DIAGNOSTICS THE INDOOR BLOWER MOTOR ARE NOT NEEDING TO BE PULLED TO BE CLEANED/CLEANED WITHOUT PULLING THE CONDENSER FAN MOTORS ARE SHOWING MORE DAMAGE THAN INITIALLY FOUND /RECOMMEND REPLACING BOTH FAN MOTORS REPLACED 1115 RPM CONDENSER FAN MOTOR @2/WITH ECM MOTORS CHEMICALLY CLEANED EVAPORATOR COILS@2 REPLACED 15MFD RUN CAPACITOR @2 CLEANED CONDENSER @2 DIDN'T NEED TO REPLACE 7.5 RUN CAPACITOR

Near S Val Vista Dr, Gilbert, AZ 85296
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION @2 TRANE /EAST/08-2004 YSC060A3RLA1JD001-------- 434100341L TRANE /WEST /08-2004 YSC060A3RLA1JD001-------- DIAGNOSIS @2 7.5 MFD RUN CAPACITOR FOR THE CONDENSER FAN MOTOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING 15MFD RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING EVAPORATOR COIL ,INDOOR BLOWER WHEEL AND CONDENSER COIL IS DIRTY/THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSOR /LOWER THE OVERALL EFFICIENCY OF THE UNIT CONDENSER FAN MOTORS ARE SHOWING HEAT/WEATHER WEAR BUT NOT OVER AMPING AT THIS TIME FILTERS ARE DIRTY /THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSORS TIGHTENED ALL ELECTRICAL CONNECTIONS

Near S Val Vista Dr, Gilbert, AZ 85296
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE 2@20-24-1 1@20-22-1 4@14-20-2 5@20-20-1

Near Spectrum Way, Gilbert, AZ 85295
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON SPLIT HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURES RATING TIGHTENED ELECTRICAL CONNECTIONS CHECKED TEMPERATURE SPLIT TESTED STATIC PRESSURE OF AIRFLOW INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. CUSTOMER IS RENEWING PMP ACCOUNT.

Near E Oakland St, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM SRP INSPECTION 1 UNIT CARRIER 24AAA660A0030010 1215E29698 DIAGNOSIS 70/7.5 DUAL RUN CAPACITOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE COMPRESSOR AND CONDENSER FAN MOTOR CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL PREMATURELY WE RECOMMEND REPLACING THE MOTOR SOON VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT WITH A 20 DEGREE SPLIT ACROSS THE COIL TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near E Tulsa St, Gilbert, AZ 85295
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON GAS FURNACE AND CONVENTIONAL AC CHECKED AMP DRAWS OF MOTORS TESTED CAPACITORS FOR PERFORMANCE VERIFIED TEMPERATURE RISE AND SPLIT TESTED PRESSURE SAFETY SWITCH TESTED FLAME SENSOR SAFETY SWITCH TESTED FLAME ROLL OUT SAFETY TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY AT TIME OF INSPECTION. UNIT SHOWS WEAR CONSISTENT WITH AGE BUT IS PERFORMING TO MANUFACTURERS SPECIFICATIONS

Near W Scott Ave, Gilbert, AZ 85233
Chris R.

Chris R.

PROBLEM 1ST PMP VISIT/3 LEFT CARRIER CA16NA04200GBAAA 0113E10278 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL/ MAY FAIL THIS SUMMER THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSOR 7.5 RUN CAPACITOR HAS FAILED FOR THE INDOOR BLOWER MOTOR /MOTOR MAY HAVE TAKEN INTERNAL DAMAGE UNIT IS SHOWING GENERAL WEAR DUE TO AGE AND USAGE REPAIRS REPLACED 1/5 HP 810 RPM CONDENSER FAN MOTOR REPLACED 7.5 RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR TIGHTENED ALL ELECTRICAL HOSED OFF OUTDOOR

Near S Cupertino Dr, Gilbert, AZ 85295
Keith H.

Keith H.

PERFORM FALL HEATING INSPECTIONS ON TWO SPLIT SYSTEM UNITS. DIAGNOSIS: BOTH UNITS ARE HEATING JUST FINE. BOTH UNITS USE ELECTRIC HEAT HEAT STRIPS. THE MAIN HOUSE HAS A 10KW HEATSTRIP AND THE GUEST HOUSE IS A 7.5 KW. BOTH HEAT STRIP KITS ARE WORKING AND SHOWING GOOD HEAT. BOTH HEAT STRIPS SHOWING GOOD AMP DRAWS. I WAS ABLE TO TIGHTEN THE ELECTRICAL CONNECTIONS IN BOTH UNITS. AT THIS TIME I DO NOT SEE ANYTHING WRONG WITH HOW THE SYSTEMS ARE HEATING. DURING THIS VISIT I HOSED OFF THE OUTDOOR COILS AS THEY APEARED DUSTY AND DIRTY. WEATHER MASTERS ONLY RECOMMENDATION AT T HIS TIME IS TO HAVE THE EQUIPMENTS CHECKED OUT IN THE SPRING FOR THE COOLING SERVICE.

Near S 157th Pl, Gilbert, AZ 85297