Weather Masters, Inc.  provides plumbing, heating  & Air Conditioning repair and installation services in Gilbert, AZ and surrounding areas. Check out what some of our customers are saying about Weather Masters, Inc. Plumbing, Heating & Air Conditioning services.

Local Reviews
for Gilbert, AZ

Rated 5.0 out of 5 stars based on 4 customer reviews

Map of Gilbert, AZ

Great Service!




Jason was very friendly and knowledgeable! I always know I’m in good hands with Weather Masters. There’s never any up-selling, just honest, hard work. It’s great working with a company you can trust. I also love their maintenance program. I never have to remember to schedule an appointment for a tune-up with this program. Every 6 months, I receive a reminder.


Map of Gilbert, AZ

Great tech




Tech did a good job


Map of Gilbert, AZ

Good Service





Map of Gilbert, AZ

A/C Proposal




Chris was on time and very informative. My A/C is pretty old and I am trying to determine how much I need to have to replace my unit.


Chris R.

Chris R.

PROBLEM NO COOL 16290 GOODMAN CK42-1C 9704146688 DIAGNOSIS LOW VOLT SHORT AT T-STAT REPLACED T-STAT /HONEYWELL 6000 PROGRAMMABLE UNIT SHOWING HEAVY WEAR DUE TO AGE AND USAGE /BUT COOLING AT THIS TIME RECOMMEND REPLACING THE UNIT

Near S Roanoke St, Gilbert, AZ 85296
Stuart M.

Stuart M.

PROBLEM UPSTAIRS UNIT NOT COOLING DIAGNOSIS: EVAPORATOR COIL LEAKING R22 REFRIGERANT. COIL MUST BE REMOVED AND REPLACED AND UNIT CHARGED WITH R22 REFRIGERANT.

Near S Griswold St, Gilbert, AZ 85297
Chris R.

Chris R.

7.5 MFD RUN CAPACITOR @2 15 MFD RUN CAPACITOR @2 CHEMICALLY CLEAN EVAPORATOR COIL IN PLACE @2 CHEMICALLY CLEAN CONDENSER COIL @2 PULL AND CLEAN BLOWER WHEEL@2 REPLACE 20-25-1 FILTERS @4 AFTER FURTHER DIAGNOSTICS THE INDOOR BLOWER MOTOR ARE NOT NEEDING TO BE PULLED TO BE CLEANED/CLEANED WITHOUT PULLING THE CONDENSER FAN MOTORS ARE SHOWING MORE DAMAGE THAN INITIALLY FOUND /RECOMMEND REPLACING BOTH FAN MOTORS REPLACED 1115 RPM CONDENSER FAN MOTOR @2/WITH ECM MOTORS CHEMICALLY CLEANED EVAPORATOR COILS@2 REPLACED 15MFD RUN CAPACITOR @2 CLEANED CONDENSER @2 DIDN'T NEED TO REPLACE 7.5 RUN CAPACITOR

Near S Val Vista Dr, Gilbert, AZ 85296
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION @2 TRANE /EAST/08-2004 YSC060A3RLA1JD001-------- 434100341L TRANE /WEST /08-2004 YSC060A3RLA1JD001-------- DIAGNOSIS @2 7.5 MFD RUN CAPACITOR FOR THE CONDENSER FAN MOTOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING 15MFD RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING EVAPORATOR COIL ,INDOOR BLOWER WHEEL AND CONDENSER COIL IS DIRTY/THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSOR /LOWER THE OVERALL EFFICIENCY OF THE UNIT CONDENSER FAN MOTORS ARE SHOWING HEAT/WEATHER WEAR BUT NOT OVER AMPING AT THIS TIME FILTERS ARE DIRTY /THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSORS TIGHTENED ALL ELECTRICAL CONNECTIONS

Near S Val Vista Dr, Gilbert, AZ 85296
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE 2@20-24-1 1@20-22-1 4@14-20-2 5@20-20-1

Near Spectrum Way, Gilbert, AZ 85295
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON SPLIT HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURES RATING TIGHTENED ELECTRICAL CONNECTIONS CHECKED TEMPERATURE SPLIT TESTED STATIC PRESSURE OF AIRFLOW INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. CUSTOMER IS RENEWING PMP ACCOUNT.

Near E Oakland St, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM SRP INSPECTION 1 UNIT CARRIER 24AAA660A0030010 1215E29698 DIAGNOSIS 70/7.5 DUAL RUN CAPACITOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE COMPRESSOR AND CONDENSER FAN MOTOR CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL PREMATURELY WE RECOMMEND REPLACING THE MOTOR SOON VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT WITH A 20 DEGREE SPLIT ACROSS THE COIL TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near E Tulsa St, Gilbert, AZ 85295
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON GAS FURNACE AND CONVENTIONAL AC CHECKED AMP DRAWS OF MOTORS TESTED CAPACITORS FOR PERFORMANCE VERIFIED TEMPERATURE RISE AND SPLIT TESTED PRESSURE SAFETY SWITCH TESTED FLAME SENSOR SAFETY SWITCH TESTED FLAME ROLL OUT SAFETY TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY AT TIME OF INSPECTION. UNIT SHOWS WEAR CONSISTENT WITH AGE BUT IS PERFORMING TO MANUFACTURERS SPECIFICATIONS

Near W Scott Ave, Gilbert, AZ 85233
Chris R.

Chris R.

PROBLEM 1ST PMP VISIT/3 LEFT CARRIER CA16NA04200GBAAA 0113E10278 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL/ MAY FAIL THIS SUMMER THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSOR 7.5 RUN CAPACITOR HAS FAILED FOR THE INDOOR BLOWER MOTOR /MOTOR MAY HAVE TAKEN INTERNAL DAMAGE UNIT IS SHOWING GENERAL WEAR DUE TO AGE AND USAGE REPAIRS REPLACED 1/5 HP 810 RPM CONDENSER FAN MOTOR REPLACED 7.5 RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR TIGHTENED ALL ELECTRICAL HOSED OFF OUTDOOR

Near S Cupertino Dr, Gilbert, AZ 85295
Keith H.

Keith H.

PERFORM FALL HEATING INSPECTIONS ON TWO SPLIT SYSTEM UNITS. DIAGNOSIS: BOTH UNITS ARE HEATING JUST FINE. BOTH UNITS USE ELECTRIC HEAT HEAT STRIPS. THE MAIN HOUSE HAS A 10KW HEATSTRIP AND THE GUEST HOUSE IS A 7.5 KW. BOTH HEAT STRIP KITS ARE WORKING AND SHOWING GOOD HEAT. BOTH HEAT STRIPS SHOWING GOOD AMP DRAWS. I WAS ABLE TO TIGHTEN THE ELECTRICAL CONNECTIONS IN BOTH UNITS. AT THIS TIME I DO NOT SEE ANYTHING WRONG WITH HOW THE SYSTEMS ARE HEATING. DURING THIS VISIT I HOSED OFF THE OUTDOOR COILS AS THEY APEARED DUSTY AND DIRTY. WEATHER MASTERS ONLY RECOMMENDATION AT T HIS TIME IS TO HAVE THE EQUIPMENTS CHECKED OUT IN THE SPRING FOR THE COOLING SERVICE.

Near S 157th Pl, Gilbert, AZ 85297
Keith H.

Keith H.

WEATHER MASTERS WILL REMOVE AND REPLACE MINI SPLIT OUTDOOR UNIT CONTROL CIRCUIT BOARD. INSTALL NEW OEM FACTOR BOARD. 2-25-19 REPAIR: WEATHER MASTERS INSTALLED A NEW CARRIER FACTORY MINI SPLIT CONDENSER MAIN CONTROL BOARD. WEATHER MASTERS TESTED THE UNIT TO ENSURE THE OUTDOOR UNIT DOES TURN ON AND OFF LIKE IT SHOULD.. THE SYSTEM WAS COOLING WITH A 30 DEG SPLIT. THE SYSTEM IS RUNNING NOW LIKE IT IS SUPPOSED TOO WITH NO ISSUES.

Near Mercy Rd, Gilbert, AZ 85297
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Keith H.

Keith H.

NOT A REAL INVOICE - CUSTOMER MOVED RECOGNIZING PMP INCOME

Near S Sulley Dr, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT FIRST CO. 18HX5-240 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING AT THIS TIME AMPS FOR ELECTRIC HEAT IS 21 AMP/THIS IS WITHIN RANGE NO RECOMMENDED REPAIRS AT THIS TIME

Near E Oakland St, Gilbert, AZ 85295
Chris R.

Chris R.

ELECTRONIC LEAK SEARCH ON THE CONDENSER NOT ABLE TO FIND A LEAK AT THIS TIME SYSTEM #1

Near N Lindsay Rd, Gilbert, AZ 85234
Chris R.

Chris R.

PROBLEM PREFORMED ELECTRONIC LEAK SEARCH ON SYSTEM 1 BLD# RM1-10 UNABLE TO VERIFY LEAK AT THIS TIME ADDED 25LBS REFRIGERANT

Near N Lindsay Rd, Gilbert, AZ 85234
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE NO ACCESS TO THE ROOF 2/14/19 REPLACED 8@16-25-2

Near S Val Vista Dr, Gilbert, AZ 85295