Weather Masters, Inc.  provides plumbing, heating  & Air Conditioning repair and installation services in Gilbert, AZ and surrounding areas.

Check out what some of our customers are saying about Weather Masters, Inc.

Local Reviews
for Gilbert, AZ

Weather Masters, Inc. Rated 5.0 out of 5 stars based on 11 customer reviews

Map of Gilbert, AZ

Great Service




Review of Weather Masters, Inc.


Map of Gilbert, AZ

Delightful!




Review of Weather Masters, Inc.

Your rep. was very knowledgeable, efficient, polite and delightful to wark with. Thanx!


Map of Gilbert, AZ

Great service




Review of Weather Masters, Inc.

Quick to schedule and Jason was very conscientious.


Map of Gilbert, AZ

Tech was amazing




Review of Weather Masters, Inc.

Keith was so extremely helpful when giving me a second opinion. He was informative and helpful and explained everything to me because I am a new home owner. I felt like he was being completely honest with me instead of trying to upsell me or tell me there were problems so I’d purchase a new unit. He was professional and thorough and even drew out pictures to help me understand the issue. I’d recommend this company and when I do buy a new unit I’ll happily go through them.


Map of Gilbert, AZ

Great




Review of Weather Masters, Inc.

Chris was great, very happy with the service and looking forward to having him continue servicing our a/c needs.


Map of Gilbert, AZ

Great Service, Great Technician




Review of Weather Masters, Inc.

I have used WeatherMasters for at least 25 years. I have never been disappointed and always appreciate their professionalism and quick. They feel more like family.


Map of Gilbert, AZ

Jason is great




Review of Weather Masters, Inc.

Excellent communication and explanation


Map of Gilbert, AZ

Great Service!




Review of Weather Masters, Inc.

Jason was very friendly and knowledgeable! I always know I’m in good hands with Weather Masters. There’s never any up-selling, just honest, hard work. It’s great working with a company you can trust. I also love their maintenance program. I never have to remember to schedule an appointment for a tune-up with this program. Every 6 months, I receive a reminder.


Map of Gilbert, AZ

Great tech




Review of Weather Masters, Inc.

Tech did a good job


Map of Gilbert, AZ

Good Service




Review of Weather Masters, Inc.


Jason G.

Jason G.

Summer inspection

Near E Bruce Ave, Gilbert, AZ 85234
Stuart M.

Stuart M.

PROBLEM: DOWNSTAIRS UNIT NOT COOLING DIAGNOSIS: TSTAT NOT CALLING FOR COOLING DUE TO LOW BATTERY. REPLACED BATTERY AND UNIT RAN NORMALLY IN COOLING.

Near S Marina Dr, Gilbert, AZ 85233
Stuart M.

Stuart M.

PROBLEM: UNITS IN MAIN ROOM NOT COOLING DIAGNOSIS: UNITS WERE SHUT OFF AT OUT DOOR DISCONNECT NOT ALLOWING COMPRESSORS OR OUTDOOR FAN MOTORS TO TURN ON. DISCONNECT WAS SWITCHED ON AND BOTH UNITS RUNNING IN COOLING

Near Spectrum Way, Gilbert, AZ 85295
Stuart M.

Stuart M.

PROBLEM: UPSTAIRS UNIT NOT COOLING DIAGNOSIS: DUAL 60/5 MF RUN CAPACITOR FAILED CAUSING COMPRESSOR NOT TO TURN ON. COMPONENT WAS REPLACED AND UNIT RUNNING IN COOLING. DUE TO COMPRESSOR OPERATING WITH FAILED CAPACITOR IT MAY HAVE SUSTAINED PERMANENT INTERNAL DAMAGE. UPSTAIRS UNIT HAS BROKEN HANDLE ON DISCONNECT. DISCONNECT MUST BE OPENED BY PRYING.

Near E Devonshire Ct, Gilbert, AZ 85297
Chris R.

Chris R.

1/4" floats 39-27-8 pads A-57 belt $601

Near W Harvard Ave, Gilbert, AZ 85233
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON TWO PACKAGE GAS AC UNITS CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERIFIED TEMP SPLIT ACROSS COILS CHECKED IN RUSH AMPS OF COMPRESSORS TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNITS BOTH UNITS RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near S Marina Dr, Gilbert, AZ 85233
Keith H.

Keith H.

RATTLE IN THE FURNACE. I WAS ABLE TO FIND THE ISSUE AS TO WHY THE FURNACE WAS RATTTLING. I WAS ABLE TO ADJUST THE HEAT EXCHANGER TO ELIMINATE THE NOISE. ALSO THE RATTLE THE HOMEOWNER WAS HEARING DOWNSTAIRS WAS THE CEILING REGISTER. I WAS ABLE TO ADJUST THE REGISTER TO ELIMINATE THE NOISE. THE SYSTEM IS RUNNING QUIET NOW .

Near S Kolb St, Gilbert, AZ 85297
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON TWO SPLIT GAS AC UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERIFIED TEMP SPLIT ACROSS COILS CLEANED OUTDOOR COILS TIGHTENED ELECTRICAL CONNECTIONS CHECKED IN RUSH AMPS OF COMPRESSORS INSPECTED CONDITION OF UNITS BOTH UNITS RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS INSTALLATION OF START ASSIST CAPACITORS TO HELP PROLONG LIFE OF COMPRESSORS. WEATHER MASTERS ALSO RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near E Horseshoe Ave, Gilbert, AZ 85296
Chris R.

Chris R.

CHEMICALLY CLEAN EVAPORATOR COIL IN PLACE CLEANED EVAPORATOR COIL

Near N Cliffside Dr, Gilbert, AZ 85234
Keith H.

Keith H.

PROVIDE SECOND OPINION FOR CONDENSATE LEAK AND OVERALL CONDTION OF A/C DIAGNOSIS: AT THIS TIME THE SYSTEM IS NO LONGER LEAKING CONDENSATE. IT DOES APPEAR THE SYSTEM HAD A CLOGGED CONDENSATE LINE. WATER WAS MORE THEN LIKLY OVER FLOWING THE PRIMARY PAN AND BEING BLOWN INTO THE SUPPLY PLENUM. DUE TO THE WAY THE EQUIPMENT WAS INSTALLED THE SECONDARY DRAIN PAN WILL NOT CATCH DRIPING WATER FROM THE PLENUMS. AFTER SPEAKING WITH BETH ABOUT THE OVER ALL CONDITION OF THE SYSTEM AND HOW UNHEALTHY THE COMPRESSOR SOUNDS. WEATHER MASTERS RECOMMENDS REPLACING THE A/C SYSTEM WITH A MORE RELIABLE AND MORE EFFICIENT SYSTEM. BETH AND I SPOKE ABOUT THE OPTION OF REPLACING THE STRAIGHT COOL GAS FURNACE WITH A NEW HEAT PUMP SYSTEM.

Near S Bridal Vail Dr, Gilbert, AZ 85297
Stuart M.

Stuart M.

PERFORMED PMP INPECTION ON 2 SPLIT GAS AC UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERFIED TEMP SPLITS ACROSS COILS CLEANED OUTDOOR COILS TIGHTENED ELECTRICAL CONNECTIONS TESTED INRUSH AMPS OF COMPRESSORS INSPECTED CONDITION OF UNITS UNITS RUNNING IN COOLING AT TIME OF INSPECTION. SOUTH UNIT COMPRESSOR PULLING HIGH IN RUSH AMPS AND MAKING MINOR NOISE ON START-UP. START ASSIST CAPACITOR WAS INSTALLED AT TIME OF INSPECTION AND BROUGHT IN RUSH AMPS DOWN TO 22 FROM 79. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near S Boulder Ct, Gilbert, AZ 85295
Chris R.

Chris R.

MIDEA 36CN1-M14C C704513920417A221400006 FURN GMTH070-4A 0211629447 COIL HT-4248 03037048301 R22

Near E Meadowview Dr, Gilbert, AZ 85298
Chris R.

Chris R.

PROBLEM NO COOL UNIT #3 50HJQ006---521HY 0707G10620 DIAGNOSIS INTERMITTENT LOW VOLT SHORT PREFORMED LOW VOLT SHORT TRACE /I WAS ABLE TO STOP THE SHORT CAN'T PIN POINT WHAT PORTION OF THE WIRE IS SHORTING AT THIS TIME/WE WILL NEED TO REWIRED THE THE CIRCUIT IF IT HAPPENS AGAIN

Near Mercy Rd, Gilbert, AZ 85297
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION GOODMAN SSZ140421AJ 1503006902 DIAGNOSIS DIRTY EVAPORATOR COIL /THIS WILL LIQUEFY THE REFRIGERANT AND CAUSE INTERNAL DAMAGE TO THE COMPRESSOR /RECOMMEND CHEMICALLY CLEANING THE EVAPORATOR COIL IN PLACE 45/5 DUAL RUN CAPACITOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME UNIT COOLING BUT WE CAN'T VERIFY CHARGE UNTIL WE CLEAN THE COIL TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near N Cliffside Dr, Gilbert, AZ 85234
Stuart M.

Stuart M.

WEATHER MASTERS CAME TO FOLLOW UP ON THE NEW SYSTEM AND MAKE SURE THERE ARE NO ISSUES. THE CHARGE ON THE SYSTEM WAS CHECKED. THE CHARGE IS OPTIMAL FOR THE UNIT. SUPER HEAT OF 13 AND SUBCOOL OF 12. THE SYSTEM IS OPERATING NORMALLY AT THIS TIME.

Near E Caleb Way, Gilbert, AZ 85234
Stuart M.

Stuart M.

WO 16959 PROBLEM: SYSTEM NOT BLOWING COLD AIR DIAGNOSIS: UNIT IS LOW ON CHARGE DUE TO LEAK FOUND ON EVAP COIL RECOMMENDED REPAIR: REPLACE EVAP COIL AND REFRIGERANT

Near E Meadowview Dr, Gilbert, AZ 85298
Stuart M.

Stuart M.

PROBLEM: SYSTEM NOT COOLING AND OUTSIDE UNIT MAKING LOUD SOUND DIAGNOSIS: UNIT IS COMPLETELY OUT OF REFRIGERANT. A LEAK WAS FOUND IN EVAP COIL RECOMMEND REPAIR: EVAP COIL REPLACMENT AND PUT 410A IN SYSTEM.

Near E Franklin Ave, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS NORTH DAY AND NIGHT PHJ442000KTPOA1 C171999507 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL AND OVER HEATING /MAY BE FAILING DURING HEAT OF THE DAY/SHAFT AND BEARING DAMAGE/WE WILL REPLACE MOTOR UNDER WARRANTY /LABOR COST ONLY COMPRESSOR MAY HAVE TAKEN INTERNAL DAMAGE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE COIL NO OTHER ISSUES AT THIS TIME COMPRESSOR AND INDOOR BLOWER MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME RHEEM #FADED RUN CAPACITOR FOR THE CONDENSER AND INDOOR BLOWER HAVE FAILED /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTORS RECOMMEND REPLACING BOTH CAPS DUE TO AGE AND CONDITION OF THIS UNIT WE DON'T RECOMMEND ANY COSTLY REPAIRS THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL AMPS FOR ALL MOTORS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME REPAIRS REPLACE OEM CONDENSER FAN MOTOR UNDER WARRANTY /LABOR ONLY TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near S Lindsay Rd, Gilbert, AZ 85295
Chris R.

Chris R.

PROBLEM 37PT INSPECTION NORDYNE FT4BF-060KA FTD090702661 DIAGNOSIS WEAK 80 MFD RUN CAPACITOR FOR THE COMPRESSOR /THIS WILL ALLOW INTERNAL DAMAGE TO THE COMPRESSOR /RECOMMEND REPLACING THE CAP SOON IMPROPERLY PIPED CONDENSATE DRAIN/SAFTEY FLOAT SWITCH IS INSTALLED ON THE PRIMARY SIDE OF THE COIL AND THE SECONDARY DRAIN IS NOT PLUGGED /THIS WILL ALLOW WATER TO OVER FLOW INTO THE SECONDARY DRAIN PAN VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL REFRIGERANT CHARGE IS OK AT THIS TIME ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN REPAIRS REPLACED 80 MFD RUN CAPACITOR UNDER WARRANTY REPAIRED DRAIN UNDER WORKMANSHIP WARRANTY

Near E Austin Dr, Gilbert, AZ 85296
Stuart M.

Stuart M.

Wo#16262 PROBLEM 37 POINT INSPECTION WEATHER MASTERS PERFORMED THE FOLLOWING: -TIGHTENED ELECTRICAL CONNECTIONS -CHECKED DISCONNECT. DISCONNECT SHOWING WEAR -AMPS ON INDOOR AND OUTDOOR FAN ARE OPTIMAL -CAPACITOR IS WITHIN RANGE -SUPERHEAT OF 15 PRESSURES AND FREON LEVELS ARE GOOD -TEMPERATURE SPLIT IS GOOD AT 18 DEGREES -THERMOSTAT WORKING -SYSTEM IS MISSING FILTER DRIERS AND INSULATION ON OUTSIDE SUCTION LINE -LARGE DENT IN CONDENSER. IS WORKING AS SHOULD THOUGH -FURNACE IS WORKING AS IT SHOULD AT THIS TIME THE SYSTEM IS OPERATING NORMALLY

Near E Redfield Ct, Gilbert, AZ 85234
Stuart M.

Stuart M.

PROBLEM: THERMOSTAT NOT PROPERLY DISPLAYING CORRECT AMBIENT TEMPERTATURE THEREFORE UNIT STAYED ON LONGER THAN NECCESARY DIAGNOSIS: THERMOSTAT IS VERY OLD AND WEATHER MASTERS RECOMMENDS REPLACEMENT REPAIR: WEATHER MASTERS REPLACED 20 YEAR OLD LUX THERMOSTAT WITH A HONEYWELL 5000. UNIT IS NOW OPERATING NORMALLY

Near W Orange Dr, Gilbert, AZ 85233
Chris R.

Chris R.

CHECK CHARGE

Near S 179th Way, Gilbert, AZ 85298
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION DAY AND NIGHT PHD342000K000C1 C111558697 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL /THIS IS WITHIN MANUFACTURE SPECIFICATIONS THE 45/5 DUAL RUN CAPACITOR IS SHOWING WEAR /WE RECOMMEND REPLACING AT THE WINTER INSPECTION /THIS WILL HELP EXTEND THE LIFE OF THE MOTORS NO OTHER ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN SEE ATTACHED FOR RECOMMENDATIONS

Near E Tremaine Ave, Gilbert, AZ 85234
Chris R.

Chris R.

PROBLEM CHECK CHARGE

Near S Griswold St, Gilbert, AZ 85297
Chris R.

Chris R.

PROBLEM SRP INSPECTION DAY AND NIGHT N4H442GKG101 E171209002 DIAGNOSIS UNIT IS A LITTLE LOW ON REFRIGERANT CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL PREMATURELY CONDENSER FAN MOTOR IS AFTER MARKET W/M DID THIS PER RON FROM AIRECOLD DUE TO NOISE ISSUES FROM THE OEM MOTOR 12.5 RUN CAPACITOR FOR THE THIS MOTOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED NEXT VISIT O OTHER ISSUES AT THIS TIME REPAIRS ADDED 1LBS OF REFRIGERANT TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near E Lakeside Dr, Gilbert, AZ 85234