Stuart M.

PERFORMED 37 POINT INSPECTION ON SPLIT HEATPUMP UNIT CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURES RATING TIGHTENED ELECTRICAL CONNECTIONS VERFIED TEMP SPLIT ACROSS COIL CHECKED STATIC PRESSURE OF DUCTWORK CLEANED OUTDOOR COIL INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. INDOOR COIL HAS SOME RUST CORROSION CONSISTENT WITH AGE. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SEASON

Near E Del Rio Dr, Queen Creek, AZ 85140
Chris R.

Chris R.

PROBLEM 2ND PMP VISIT 1 UNIT ICP PHJ 360000K000A2 C140896235 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL BUT NOT OVER AMPING AT THIS TIME UNIT IS SHOWING NORMAL WEAR NO RECOMMENDED REPAIRS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near E Cherry Hills Pl, Queen Creek, AZ 85142
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION @2 /SRP MASTER DAY AND NIGHT N4H442GKG101 E170817933 KITCHEN DAY AND NIGHT N4H442GKG101 E170817917 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN HEATING AND COOLING MODE FOR BOTH UNITS BOTH UNITS HAVE THE RECOMMENDED TEMPERATURE SPLITS ACROSS THE EVAPORATOR COILS VERIFIED SEQUENCE OF OPERATION FOR THE DEFROST CYCLE /NO ISSUES AT THIS TIME 70/5 DUAL RUN CAPACITOR ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME DUE TO LOW AMBIENT TEMPERATURES WE CAN NOT PROPER VERIFY CHARGE IN THE COOLING MODE AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COILS FLUSHED DRAINS NO RECOMMENDED REPAIRS AT THIS TIME

Near South 169th Place, Queen Creek, AZ 85142
Keith H.

Keith H.

PROBLEM: S/W UNIT IS LEAKING WATER FROM THE UNDERSIDE OF THE UNIT. DIAGNOSIS: THE UNIT HAS A 1/4 IN DRAIN HOLE IN THE BOTTOM OF THE COMPRESSOR COMPARTMENT TO ALLOW CONDENSATE TO DRAIN OFF THE FREON LINES.. THIS IS NOT PART OF THE NORMAL CONDENSATE LINE. REPAIR: AT THIS TIME OF VISIT I DID FLUSH THE MAIN CONDESATE LINE TO ENSURE IT IS CLEAR AND DRAINING. I DID INSPECT THE COMPRESSOR COMPARTMENT DRAIN AND IT IS DRAINING CORRECTLY. THE UNIT IS NOT DESIGNED TO HAVE A DRAIN LINE ATTACHED TO THE COMPRESSOR COMPARTMENT. THIS WILL ALLOW WATER TO DRAIN ONTO THE UNIT METAL CURB AND ROOF. THE AMOUNT OF WATER IS NORMALY NOT ENOUGH TO WARRANTY A DRAIN LINE DUE TO EVAPORATION.

Near S Ellsworth Rd, Queen Creek, AZ 85142
Chris R.

Chris R.

FILTER MAINTENANCE

Near S Ellsworth Rd, Queen Creek, AZ 85142
Nicole  P.

Nicole P.

COMPRESSOR IS GRINDING DUE TO AGE AND CONDITION WEATHER MASTERS RECOMMENDS REPLACEMENT OF THE UNIT WEATHER MASTERS REMOVE AND HAUL AWAY EXISTING 5 TON COMMERCIAL PACKAGE HEAT PUMP INSTALL NEW 5 TON COMMERCIAL PACKAGE HEAT PUMP WITH CURB ADAPTER REPLACE 3 PHASE DICONNECT AND FUSES RECONNECT TO EXISTING ELECTRICAL AND ROOF DRAIN PROVIDE CRANE SERVICE START UP AND ENSURE PROPER OPERATION PO#512911318

Near E Ocotillo Rd, Queen Creek, AZ 85142
Nicole  P.

Nicole P.

MOVE T- STATS PO# 512911320

Near E Ocotillo Rd, Queen Creek, AZ 85142
Chris R.

Chris R.

PROBLEM NO HEAT TRANE MFD:5/2007 WSC060A3ROA28000000000000A 718102276L DIAGNOSIS MAJOR RESTRICTION IN HEATING AND COOLING MODE PREFORMED ELECTRONIC LEAK SEARCH AND FOUND LEAKS AT THE SHREDDER CORE ON THE DISCHARGE LINE AND THE DISTRIBUTOR FEEDING THE CONDENSER COIL FOUND OIL IN THE CONDENSER CABINET CONDENSER FAN MOTOR IS LEAKING OIL COMPRESSOR HAS TAKEN PERMANENT INTERNAL DAMAGE DUE TO THE AGE AND CONDITION OF THIS UNIT WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM

Near E Ocotillo Rd, Queen Creek, AZ 85142
Keith H.

Keith H.

PROBLEM: NO HEAT. SYSTEM HAS HAD AN INTERMITTEN ISSUE THAT HAS KEPT THE FURNACE FROM RUNNING CORRECTLY. TODAY WE WERE ABLE TO DETERMINE THAT THE UNIT WAS LOCKED OUT ON HIGH LIMIT SWITCH, AFTER LOOKING FURTHER AT THE FURNACE WE FOUND THE CAPACITOR FOR THE INDOOR FAN MOTOR TO BE VERY WEAK AND DRAWING HIGHER AMPS. WEATHER MASTERS REPLACED THE 10MFD RUN CAPACITOR AND NOW THE BLOWER MOTOR IS DRAWING LOWER AMPS. WEATHER MASTERS FEELS THAT THIS SHOULD RESOLVE THE ISSUE BUT IF THE PROBLEM HAPPENS AGAIN, CALL US BACK OUT TO RECHECK THE LIMIT SWITCHS. WEATHER MASTER WILL BRING A SET OF NEW LIMIT SWITCHES TO REPLACE THEM IF THE PROBLEM ACCURES AGAIN.

Near E Caledonia Dr, Queen Creek, AZ 85142
Keith H.

Keith H.

PROBLEM: UNIT NOT TURNING ON WHEN CALLING FOR HEAT DIAGNOSIS: UNIT RUNNING NORMALLY AT THIS TIME WHEN CALLING FOR HEAT FROM TSTAT. VERIFIED UNIT HAS THE CORRECT TEMPERATURE RISE SET BY MANUFACURER WEATHER MASTERS RECOMMENDS IF PROBLEM PERSISTS FOR HOMEOWNER TO SET TSTAT ABOVE 90 DEGREES AND LEAVE CALLING FOR HEAT UNTIL A TECHNICIAN CAN ARRIVE TO ALLOW THE CONTROL BOARD TO SHOW THE APPLICABLE ERROR CODE

Near E Caledonia Dr, Queen Creek, AZ 85142
Chris R.

Chris R.

PROBLEM NO HEAT DIAGNOSIS FURNACE WAS NEEDED TO BE RESET /THE CAUSE MAY BE GAS PRESSURE TO HIGH AND DIRTY FILTER /UNIT SHUT OFF ON HIGH LIMIT ADJUSTED GAS PRESSURE AND CHANGED FILTER GAS PRESSURES AND TEMPERATURE RISE ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CHECKED FOR CARBON MONOXIDE /DID NOT DETECT ANY AT THIS TIME WE STRONGLY RECOMMEND CARBON MONOXIDE DETECTORS IN THE HOME

Near E Caledonia Dr, Queen Creek, AZ 85142
Chris R.

Chris R.

PROBLEM DAY AND NIGHT N8MSL0701716A1 A132215781 DIAGNOSIS CHECKED THE SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT HEATING WITH MANUFACTURE RECOMMENDED TEMP RISE ACROSS THE HEAT EXCHANGER AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME WEATHERMASTERS RECOMMENDS HAVING A CARBON MONOXIDE DETECTOR IN THE HOME UNIT IS HEATING WITH NO ISSUES AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME

Near N Coral Bean Dr, Queen Creek, AZ 85143
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS DAY AND NIGHT KITCHEN N8MSL0701716A3 A171019808 MASTER BED DAY AND NIGHT N8MSL0902120A3 A171021263 DIAGNOSIS CHECKED BOTH UNITS IN HEATING/BOTH UNITS ARE HEATING WITH RECOMMENDED MANUFACTURERS TEMP RISE ACROSS THE HEAT EXCHANGER AMP RATING ARE WITHIN MANUFACTURE SPECIFICATIONS UNITS ARE WORKING WITH NO ISSUES AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME