Weather Masters, Inc.  provides plumbing, heating  & Air Conditioning repair and installation services in Scottsdale, AZ and surrounding areas.

Check out what some of our customers are saying about Weather Masters, Inc.

Local Reviews
for Scottsdale, AZ

Weather Masters, Inc. Rated 5.0 out of 5 stars based on 6 customer reviews

Map of Scottsdale, AZ

Efficient, informative, great price, very pleased.




Review of Weather Masters, Inc.


Map of Scottsdale, AZ

Great service and knowledgeable service technician




Review of Weather Masters, Inc.

Very comprehensive testing of furnaces


Map of Scottsdale, AZ

Great service




Review of Weather Masters, Inc.


Map of Scottsdale, AZ

Always great!!




Review of Weather Masters, Inc.


Map of Scottsdale, AZ

very efficient and friendly




Review of Weather Masters, Inc.


Map of Scottsdale, AZ

Great service




Review of Weather Masters, Inc.

Chris is excellent. Very good company


Jason G.

Jason G.

AC unit is not working at all.

Near E Thompson Peak Pkwy, Scottsdale, AZ 85255
Chris R.

Chris R.

REPLACE INDOOR BLOWER MOTOR WITH AFTER MARKET /THEY DONT MAKE THE OEM MOTOR ANYMORE PULL AND CLEAN RUSTED BLOWER WHEEL DURING MOTOR REPLACEMENT /THEY DONT MAKE THIS WHEEL ANYMORE CHEMICALLY CLEAN EVAPORATOR COIL IN PLACE WEATHER MASTERS CAN NOT WARRANTY THE OVERALL OPERATION AND EFFICIENCY OF THE UNIT DUE TO THE AGE AND CONDITION 5/15/19 WO#17120 REPLACED 1/5 HP BLOWER MOTOR WITH AFTER MARKET MOTOR/THEY DO NOT MAKE THE MOTOR ANYMORE CLEANED DAMAGED RUSTED BLOWER WHEEL /THEY DONT MAKE WHEEL ANYMORE HAD TO FABRICATE A NEW BRACKET BECAUSE THE OLD BRACKET IS PART OF THE MOTOR WEATHER MASTERS CAN NOT BE RESPONSIBLE FOR THE OPERATION OR LIFE OF THE REPAIR CHEMICALLY CLEANED EVAPORATOR COIL UNIT IS COOLING AT THIS TIME

Near E Starlight Way, Scottsdale, AZ 85250
Robert T.

Robert T.

REMOVE AND HAUL AWAY EXISTING 4 TON GAS PACK INSTALL NEW 14 SEER DAY AND NIGHT 4 TON GAS PACK 5000 T-STAT SHEET METAL TRANSITION RED WOOD SLEEPERS 1 YR LABOR 10 YR PARTS AND COMPRESSOR WEATHER MASTERS IS NOT RESPONSIBLE FOR DRYWALL /PAINT REPAIRS

Near E McDonald Dr, Scottsdale, AZ 85253
Chris R.

Chris R.

PROBLEM NO COOL CARRIER SERIAL N508848 #17149 DIAGNOSIS 5 MFD RUN CAPACITOR HAS FAILED /MOTOR HAS TAKEN PERMANENT INTERNAL DAMAGE /MAY FAIL SOON BURNED DAMAGED WIRES UNIT OVERALL IS SHOWING HEAVY HEAVY WEAR DUE TO AGE AND USAGE /RECOMMEND REPLACING SOON /WE WILL QUOTE UPON REQUEST REPLACED 5MFD RUN CAPACITOR REPAIRED BURNED DAMAGE

Near E Glenrosa Ave, Scottsdale, AZ 85251
Chris R.

Chris R.

PROBLEM PMP VISIT@3 LENNOX OFFICE 12HPB24-10P 5805B48448 MASTER 13ACC-060-230-01 5805C27151 KITCHEN 13ACC-060-230-01 5805C27152 DIAGNOSIS ALL 3 UNIT ARE SHOWING HEAVY WEAR DUE TO AGE AND USAGE RUN CAPACITORS FOR THE INDOOR BLOWER MOTOR ON THE OFFICE A/H IS WEAK /RECOMMEND REPLACING THE CAP TO HELP EXTEND THE LIFE OF THE MOTOR {7.5} ALL OTHER RUN CAPACITORS ARE SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS /THEY MAY NEED TO BE REPLACED AT NEXT VISIT MOTOR AMPS FOR ALL 3 UNITS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME ALL THREE UNITS ARE COOLING WITHPROPER TEMPERATURE SPLITS ACROSS EVAPORATOR COILS REPAIRS REPLACED 7.5 RUN CAPACITOR FOR THE INDOOR BLOWER MOTOR ON THE OFFICE UNIT TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COILS FLUSHED DRAINS

Near N 97th St, Scottsdale, AZ 85262
Stuart M.

Stuart M.

Weather Masters successfully completed a 37 point inspection on 2 units - weather Masters tightened all electrical fittings - checked all Freon levels and pressures - checked amperage of indoor and outdoor motor. Working at intended anprage -Ensured run capacitor is running with proper MFD's and is not leaking - subcool is 13 and 14 -examined indoor and outdoor coil. Outdoor coils werecleaned with water -temperature split is normal -thermostat is working as should -customer regularly changes filter so it is clean -customer says unit is working well At this time, the systems are running normally.

Near E De La O Rd, Scottsdale, AZ 85255
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION GOETTL GP4854-075C 01232255 UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE TEMPERATURE SPLIT ACROSS THE EVAPORATOR COIL IS LOW EVAPORATOR COIL IS ICING /PREFORMED LEAK SEARCH AND DETECTED A LEAK AT THE INDOOR AND OUTDOOR COILS CAN'T PIN POINT LEAK AT THIS TIME /WE WOULD NEED TO ADD DIE TO PIN POINT THE LEAK DUE TO THE AGE OF THIS UNIT WE RECOMMEND REPLACING IT UNIT MAY NOT COOL EFFICIENTLY THIS SUMMER CUSTOMER WANT TO HOLD OFF AT THIS TIME ON REPLACING THE UNIT TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL DRAIN PAN IS FULL OF DEBRIS /THIS MAY CAUSE DRAINING ISSUES WE WILL PROVIDE A QUOTE APPON REQUEST

Near E McDonald Dr, Scottsdale, AZ 85253
Stuart M.

Stuart M.

PROBLEM: CONDENSATE LINE LEAKING INTO RESIDENCE DIAGNOSIS: CONDENSATE LINE CLOGGED WAS CLEARED OUT USING NITROGEN AND FLUSHED. CONDENSATE LINE DRAINING NORMALLY AFTER SERVICE

Near N 60th St, Scottsdale, AZ 85257
Stuart M.

Stuart M.

PERFORM FILTER CHANGE ON 7 SYSTEMS. PERFORM INSPECTIONS ON 7 UNITS. DIAGNOSIS: UNIT 20- REDLINE IS NOT USING THIS SYSTEM DUE TO NO THERMOSTAT CONNECTED. CONDENSER FAN MOTOR OVER AMPING , RECOMMEND REPLACMENT. MARS ECM UNIT 18- SYSTEM WAS NOT COOLING DUE TO BLOWN FUSES. SYSTEM IS TURNED OFF TO PREVENT COMPRESSOR FAILURE TILL SYSTEM CAN BE REPAIRED. CONDENSER FAN MOTOR OVER AMPING. SYSTEM HAD BLOWN 45 AMP FUSES. CONDENSATE DRAIN LINE CRACKED. NEEDS REPLACED. RECOMMEND REPLACING CONDENSER FAN MOTOR WITH MARS ECM. RECOMMEND NEW 60MFD COMPRESSOR CAPACITOR AND KS1 HARD START COMPRESSOR KIT. RECOMMEND NEW 15MFD CAPACITOR FOR INDOOR BLOWER MOTOR. UNIT 16- SYSTEM RUNNING FINE IN COOLING JUST RECOMMEND HAVING REPAIRS DONE CONDENSER FAN MOTOR OVER AMPING . RECOMMEND NEW CONDENSER FAN MOTOR. MARS ECM . RECOMMEND NEW 60MFD CAPACITOR FOR COMPRESSOR. RECOMMEND NEW 15MFD CAPACITOR FOR INDOOR BLOWER. UNIT 19- SPLIT SYSTEM - UNIT RUNNING AND COOLING FINE. RECOMMED 5MFD CAPACITOR FOR O

Near North Hayden Road, Scottsdale, AZ 85260
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON TWO SPLIT AC ELECTRIC HEAT UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COILS TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT DOWNSTAIRS UNIT HAS WEAK DUAL CAPACITOR TESTING FAR BELOW THE MANUFACTURER'S RANGE. WEATHER MASTERS RECOMMENDS REPLACEMENT OF THIS COMPONENT AS ITS CONTINUED USE WHILE BEING WEAK MAY CAUSE THE MOTORS IT IS ATTACHED TO SUFFER PERMANENT INTERNAL DAMAGE. BOTH UNITS RUNNING IN COOLING AT TIME OF INSPECTION

Near E Pleasant Run, Scottsdale, AZ 85258
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT DAY AND NIGHT C4A48GKD200 E100802098 DIAGNOSIS 45/7.5 IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED AT NEXT VISIT ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CHARGE IS RUNNING 10 DEGREES OF SUB COOLING /UNIT CALLS FOR 12 PLUS OR MINUS 3 DEGREES /MAY NEED TO ADD AT NEXT VISIT UNIT IS COOLING WITH NO ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN

Near N 70th St, Scottsdale, AZ 85266
Chris R.

Chris R.

PROBLEM NO HEAT DIAGNOSIS INDOOR BLOWER MOTOR MOTOR IS INTERNALLY DAMAGED CAUSING THE UNIT TO CYCLE OFF ON HIGH HEAD WHEN THE MOTOR STOPS WORKING DUE TO THE AGE AND CONDITION WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM

Near N 68th St, Scottsdale, AZ 85254
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON TWO PACKAGE HEAT PUMP UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLITS ACROSS COILS TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNITS BOTH UNITS RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near E Valley View Rd, Scottsdale, AZ 85250
Chris R.

Chris R.

PROBLEM 37PT INSPECTION TRANE TTN048C100A3 P123RCJFF DIAGNOSIS 7.5 MFD RUN CAPACITOR FOR THE CONDENSER FAN MOTOR IS WEAK /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING THE CAP THE UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE /WE DON'T RECOMMEND ANY COSTLY REPAIRS CHARGE LOOKS OK AT THIS TIME BUT DUE TO THE LOW AMBIENT TEMPERATURES TODAY WE CAN NOT VERIFY POSSIBLE ISSUES THAT MAY SHOW WHEN TEMPERATURES RISE REPAIRS REPLACED 7.5 RUN CAPACITOR FOR THE CONDENSER FAN MOTOR TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near E Calle Buena Vista, Scottsdale, AZ 85255
Keith H.

Keith H.

PROBLEM: UNIT HAS A FAILED COMPRESSOR. WANTS ESTIMATE ON NEW SYSTEM. COMPRESSOR HAS BLOWN PIN.

Near E Nightingale Star Cir, Scottsdale, AZ 85266
Chris R.

Chris R.

PROBLEM RETURN TO REPLACE GAS VALVE UNDER WARRANTY /LABOR WARRANTY TESTED HEAT CYCLE NO ISSUES AT THIS TIME

Near E Voltaire Ave, Scottsdale, AZ 85254
Chris R.

Chris R.

PROBLEM NO HEAT DAY AND NIGHT C8MPV100J20C1 A082845950 MFD:JUL /08 DIAGNOSIS GAS VALVE HAS INTERMITTENT PROBLEM OPENING NEED TO ORDER VALVE/VALVE UNDER WARRANTY

Near E Voltaire Ave, Scottsdale, AZ 85254
Stuart M.

Stuart M.

WEATHER MASTERS WILL CLEAN INDOOR COIL USING CHEMICAL CLEANER AND RE-WEIGH REFRIGERANT CHARGE 3/1/19 WEATHER MASTERS RETURNED AND CLEANED INDOOR COIL USING CHEMICAL CLEANER, VERIFIED CORRECT AIR MOVEMENT ACROSS COIL, CHECKED STATIC PRESSURE IN DUCTWORK, AND CORRECTLY WEIGHED IN REFRIGERANT CHARGE. UNIT RUNNING IN HEATING AT THIS TIME. WEATHER MASTERS WILL RETURN WITHIN A FEW MONTHS TO INSPECT UNIT IN COOLING TO FURTHER VERIFY CORRECT PERFORMANCE.

Near E Sahuaro Dr, Scottsdale, AZ 85259
Stuart M.

Stuart M.

PROBLEM UNIT NOT TURNING ON DIAGNOSIS: RESIDENT CYCLING ON AND OFF UNIT FROM THERMOSTAT FASTER THAN OUTDOOR DELAY COULD BE SATISFIED. OUTSIDE UNIT IS EQUIPPED WITH 5 MINUTE DELAY TO PREVENT SHORT CYCLING. RESIDENT WASE EDUCATED AT TIME OF CALL ABOUT DELAY FEATURE ON UNIT. NO OTHER ISSUES FOUND IN HEATING.

Near N 75th Pl, Scottsdale, AZ 85251
Keith H.

Keith H.

NORTH UNIT NOT HEATING.. DIAGNOSIS: THE DUAL 45-5 RUN CAPACITOR HAS FAILED CAUSEING THE OUTDOOR FAN MOTOR TO FAIL. REPAIR: REPLACED THE DUAL 45-5 RUN CAPACITOR . TESTED THE AMP DRAWS OF THE COMPRESSOR AND OUTDOOR FAN MOTOR . AT THIS TIME THE AMP DRAWS OF BOTH THE COMPRESSOR AND ODF ARE NORMAL. RECOMMEND SPRING SERVICE FOR COOLING.

Near N 68th St, Scottsdale, AZ 85254
Stuart M.

Stuart M.

PROBLEM: UNIT MAKING LOUD NOISE ON SHUT OFF DIAGNOSIS: DUE TO LACK OF AIRFLOW FROM DIRTY INDOOR COIL AND POSSIBLE OVERCHARGE UNIT IS SHUTTING OFF ON HIGH HEAD PRESSURE CAUSING PRESSURE RELIEF INSIDE COMPRESSOR TO OPEN MAKING A LOW NOISE. WEATHER MASTERS RECOMMENDS INDOOR COIL IS CLEANED USING CHEMICAL COIL CLEANER AND AT SAME TIME WILL RECOVER EXISTING REFRIGERANT AND WEIGH IN NEW. CHARGE.

Near E Sahuaro Dr, Scottsdale, AZ 85259
Stuart M.

Stuart M.

PROBLEM: UNIT NOT HEATING DIAGNOSIS: SEVERAL SUPPLY REGISTERS WERE CLOSED OFF AND ONE HAD CARDBOARD BLOCKING IT CAUSING HIGH STATIC PRESSURE AND THE UNIT TO SHUT OFF DUE TO TEMPERATURE SAFETY BEING TRIPPED. REGISTERS WERE OPENED AND CARDBOARD WAS REMOVED AND UNIT RAN NORMALLY IN HEATING FOR AN EXTENDED PERIOD OF TIME.

Near N 84th Pl, Scottsdale, AZ 85251
Keith H.

Keith H.

PROBLEM: SUIT 1 FRONT UNIT HAS A BURING SMELL. DIAGNOSIS: AFTER A FULL INSPECTION OF THE AIR HANDLER I WAS ABLE TO FIND THE DISCONNECT TO BE BURNED UP AND BURNED UP FUSES. THE DISCONNECT WILL NEED TO BE REPLACED. REPAIR: REPLACED 30 AMP FUSED SERVICE DISCONNECT. REPAIRED BURNED LINE POWER ELECTRICAL WIRES. TESTED THE UNIT IN HEATING AND VERIFIED SYSTEM OPERATION. NOTE: THE SMELL WILL LAST FOR A FEW DAYS BUT WILL GO AWAY NOW THAT THE ELECTRICAL HAS BEEL REPAIRED

Near E Gray Rd, Scottsdale, AZ 85260
Keith H.

Keith H.

PROBLEM: SUIT 1 FRONT UNIT HAS A BURING SMELL. DIAGNOSIS: AFTER A FULL INSPECTION OF THE AIR HANDLER I WAS ABLE TO FIND THE DISCONNECT TO BE BURNED UP AND BURNED UP FUSES. THE DISCONNECT WILL NEED TO BE REPLACED. REPAIR: REPLACED 30 AMP FUSED SERVICE DISCONNECT. REPAIRED BURNED LINE POWER ELECTRICAL WIRES. TESTED THE UNIT IN HEATING AND VERIFIED SYSTEM OPERATION. NOTE: THE SMELL WILL LAST FOR A FEW DAYS BUT WILL GO AWAY NOW THAT THE ELECTRICAL HAS BEEL REPAIRED

Near E Gray Rd, Scottsdale, AZ 85260
Keith H.

Keith H.

PROBLEM: SUIT 1 FRONT UNIT HAS A BURING SMELL. DIAGNOSIS: AFTER A FULL INSPECTION OF THE AIR HANDLER I WAS ABLE TO FIND THE DISCONNECT TO BE BURNED UP AND BURNED UP FUSES. THE DISCONNECT WILL NEED TO BE REPLACED. REPAIR: REPLACED 30 AMP FUSED SERVICE DISCONNECT. REPAIRED BURNED LINE POWER ELECTRICAL WIRES. TESTED THE UNIT IN HEATING AND VERIFIED SYSTEM OPERATION. NOTE: THE SMELL WILL LAST FOR A FEW DAYS BUT WILL GO AWAY NOW THAT THE ELECTRICAL HAS BEEL REPAIRED

Near E Gray Rd, Scottsdale, AZ 85260
Keith H.

Keith H.

WO-15785 PROBLEM: NO HEAT AND NO AIRFLOW FROM THE A/C VENTS. DIAGNOSIS: THE SYSTEM HAS A VERY DIRTY INDOOR COIL AND SET OF BLOWER WHEELS. REPAIR: REMOVED THE BLOWER WHEELS AND CLEANED. REMOVED THE HEAT STRIP ELEMENTS AND CLEANED THE INDOOR COIL WITH A VAC. AND COIL CLEANER. REINSTALLED THE HEAT STRIPS AND BLOWER WHEELS. TESTED THE UNIT IN HEATING. VERIFIED THE UNIT WAS HEATING AND AT THIS TIME ITS HEATING BETTER , WITH BETTER AIR FLOW. TYPE - FIRST CO. STYLE AIR HANDLER WITH 5KW HEAT STRIPS.

Near E Roosevelt St, Scottsdale, AZ 85257
Keith H.

Keith H.

UNIT NOT HEATING. DIAGNOSIS: THERMOSTAT HAS FAILED AND NEEDS REPLACED. JOUL WANTED THE SAME THERMOSTAT BUT THEY DONT MAKE IT ANYMORE . I RECOMMEND A HONEYWEL. 8000 THERMOSTAT THAT RESEMBLES THE SAME SIZE AS ORIGINAL. REPAIR: INSTALLED NEW HONEYWELL 8000 REDLINK THERMOSTAT.

Near E Buena Terra Way, Scottsdale, AZ 85250
Chris R.

Chris R.

RETURN FOR ESTIMATE

Near N 87th Terrace, Scottsdale, AZ 85257
Chris R.

Chris R.

PROBLEM PMP VISIT 5 UNITS DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE FOR ALL 5 UNITS/ALL UNITS ARE HEATING WITHIN THE SPECIFIED TEMP RISE ACROSS THE HEAT EXCHANGERS TESTED ALL SAFTEY AND LIMIT SWITCHES /NO ISSUES AT THIS TIME UNITS ARE HEATING WITH NO ISSUES AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME

Near E Chiricahua Pass, Scottsdale, AZ 85262
Stuart M.

Stuart M.

PERFORMED PMP INSPECTION ON FOUR GAS FURNACES TESTED PRESSURE SAFTEY SWITCHES ON ALL UNITS TESTED FLAME SENSOR SAFTEY VERIFIED TEMP RISE WITHIN MANUFACTURERS RANGE CHECKED AMP DRAW OF ALL MOTORS USED DURING HEATING VERIFIED FLAME PERFORMANCE ALL UNITS RUNNING IN HEATING NORMALLY AT THIS TIME WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN SPRING FOR A/C SIDE OF SYSTEM

Near N 107th Pl, Scottsdale, AZ 85262
Chris R.

Chris R.

PROBLEM 37 PT INSPECTION MN/FADED UNIT INSTALLED 5/18/01 DIAGNOSIS UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE DIRTY BLOWER MOTOR AND WHEEL DIRTY EVAPORATOR COIL DIRTY/DAMAGED CONDENSER COIL/HAIL DAMAGE 50/5 AND 5 MFD RUN CAPACITORS ARE SHOWING WEAR SEE ATTACHED PHOTO'S AND INSPECTION SHEET FOR MORE DETAILS WE CAN PROVIDE ESTIMATE FOR REPAIRS UPON REQUEST

Near N 87th Terrace, Scottsdale, AZ 85257
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS TRANE MASTER 2TWR3042A1000AA 7023UD64F MFD:1/2007 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL 35/5 DUAL RUN CAPACITOR IS SHOWING WEAR DIRTY EVAPORATOR COIL /THIS WILL CAUSE INTERNAL DAMAGE TO THE COMPRESSOR VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING AT THIS TIME RECOMMEND CHEMICALLY CLEANING COIL IN PLACE TESTED DEFROST CYCLE /NO ISSUES TIGHTENED ALL ELECTRICAL CONNECTIONS KITCHEN TRANE 2TWR3060A1000AA 725470D2F MFD:6/2007 DIAGNOSIS CONTACTOR SHOWING WEAR COMPRESSOR CONTACTOR SHOWING WEAR 80 MFD RUN CAPACITOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME VERIFIED SEQUENCE OF OPERATION IN HEATING MODE AND THE UNIT IS HEATING AT THIS TIME DIRTY EVAPORATOR COIL /RECOMMEND CEANING TESTED DEFROST CYCLE /NO ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS BOTH UNITS ARE SHOWING GENERAL WEAR DUE TO THE AGE AND USAGE

Near N 136th St, Scottsdale, AZ 85262
Chris R.

Chris R.

PERFORMED INSPECTION ON 1 PACKAGE HEATPUMP UNIT TESTED MOTOR AMP DRAWS CHECKED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED SEQUENCE OF OPERATIONS FOR DEFROST CYCLE CHECKED FREON LEVELS TIGHTENED ELECTRICAL CONNECTIONS CHECKED TEMPERATURE SPLIT IN HEATING UNIT RUNNING IN HEATING LESS EFFICIENTLY THAN NORMAL AT TIME OF INSPECTION UNIT HAS A DIRTY INDOOR COIL DUE TO LACK OF FILTER BEING USED BY RESIDENT. WEATHER MASTERS RECOMMENDS IMMEDIATE INSTALLATION OF PROPER FILTER AND CLEAING OF INDOOR COIL. ON DAY OF INSPECTION THE AMBIENT TEMPERATURE IS NEAR 40 DEGREES AND MAY BE AFFECTING TEMP SPLIT OF UNIT. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN SPRING TO BETTER VERIFY FREON LEVELS OF UNIT.

Near E Portland St, Scottsdale, AZ 85257
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT FXM4X4800AL3 A142990199 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN HEATING MODE AND THE UNIT IS HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS EVAPORATOR COIL ELECTRIC HEAT IS PULLING PROPER AMPS MOTOR IS PULLING PROPER AMPS

Near E San Salvador Dr, Scottsdale, AZ 85258
Keith H.

Keith H.

WEATHER MASTERS PURPOSES TO REMOVE AND REPLACE CHEWED UP DISCHARGE SENSOR wire harness.

Near N 100th Ave, Scottsdale, AZ 85266
Stuart M.

Stuart M.

FILTER COUNT: (3) 20X30X2 (1) 16X20X1 (3) 20X20X1 PLS UPDATE COUNT

Near North Hayden Road, Scottsdale, AZ 85260
Stuart M.

Stuart M.

PERFORM HEATING PMP INSPECTIONS BRUCE WANTED JUST THE MAIN UNITS FOR THE HOUSE AND GUEST HOUSE DONE . NOT THE GARAGE UNITS. TESTED 5 FURNACES IN HEATING. VERFIED SEQUENCE OF OPPERATION. TESTED HIGH LIMITS AND SAFTY CONTROLS . EACH FURNANCE HEAT RISE WITHIN SPEC. BRUCE WANTED EACH CONDENSATE LINE FLUSHED . AT THIS TIME EACH FURANCE IS RUNNING IN HEATING WITH NO ISSUES.. WEATHER MASTER WILL RETURN IN THE SPRING TO INSPECT EACH A/C OUTDOOR UNIT AND COIL. AND HOSE OFF CONDENSERS

Near E Happy Valley Rd, Scottsdale, AZ 85255
Chris R.

Chris R.

PROBLEM START UP DAY AND NIGHT FEM4X3600BL4E F183035309 N4H436GKG201 E1844133274 STATIC=S/A=.2 R/A=.1 PRESSURE 199/395 AMPS:COND=.9 COMP:=15.6 WE NEED TO COME BACK TO ADJUST CHARGE IN COOLING I PULLED OUT 3.12 LBS

Near E Gray Rd, Scottsdale, AZ 85260
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT TRANE 4WHC3042A1000AA 13342HSY3H MFD:8/2013 DIAGNOSIS CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL PREMATURELY 55/5 DUAL RUN CAPACITORS IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED NEXT VISIT EVAPORATOR COIL COIL IS SHOWING SIGNS OF RUST VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING WITH A 30 DEGREE SPLIT ACROSS THE EVAPORATOR COIL TESTED DEFROST CYCLE /NO ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS NO RECOMMENDED REPAIRS AT THIS TIME

Near E Pinchot Ave, Scottsdale, AZ 85251
Chris R.

Chris R.

PROBLEM PMP VISIT 1 UNIT DAY AND NIGHT PHD348000K000C1 C114341221 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS EVAPORATOR COIL VERIFIED SEQUENCE OF OPERATION IN THE DEFROST MODE /NO ISSUES AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS UNIT IS SHOWING GENERAL WEAR DUE TO AGE AND USAGE NO RECOMMENDED REPAIRS AT THIS TIME SEE ATTACHED FOR MORE DETAILS

Near E Pecos Ln, Scottsdale, AZ 85250
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS MAIN G8MVL0902116B1 A175023647 MASTER G8MVL0902116B1 A180815813 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE FOR BOTH UNITS /BOTH UNITS ARE HEATING WITHIN THE SPECIFIED TEMP RISE ACROSS THE HEAT EXCHANGERS MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS PRESSURE AT THE GAS VALVES ARE SET CORRECT ALL SAFTEY AND LIMIT SWITCHES ARE WORKING AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME

Near E Turnberry Rd, Scottsdale, AZ 85255
Chris R.

Chris R.

PROBLEM PMP VISIT 2 UNITS GOODMAN UPSTAIRS GMS90904CXA 0503133540 DOWNSTAIRS GHS80905CHA 0502793877 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN HEATING MODE FOR BOTH UNITS/BOTH UNIT ARE HEATING WITHIN THE MANUFACTURE SPECIFIED TEMPERATURE RISE ACROSS THE HEAT EXCHANGER MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS RUN CAPACITORS ARE SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO ISSUES WITH SAFTEY OR LIMIT SWITCHES AT THIS TIME UNIT IS SHOWING WEAR DUE TO AGE AND USAGE NO RECOMMENDED REPAIRS AT THIS TIME

Near N 95th St, Scottsdale, AZ 85255
Keith H.

Keith H.

PERFORM INSPECTIONS ON 5 UNITS TESTED EACH FURNACE IN HEATING.. CHECKED PRESSURE SAFETY SWITCHES VERIFIED TEMPERATURE RISE IS WITHIN MANUFACTURE RANGE TESTED SAFETY ROLL OUT SWITCHES TESTED FLAME SENSOR SAFETY OBSERVED FLAME COLOR DIAGNOSIS ADJUSTED GAS PRESSURE AT FURNACE LOCATED IN GARAGE DUE TO HIGH TEMP RISE UNIT RUNNING NORMALLY AFTER ADJUSTMENT OTHER FURNACE UNITS RUNNING NORMALLY AT TIME OF INSPECTION UNABLE TO PERFORM INSPECTION ON MINI SPLIT SYSTEM DUE TO FAILURE OF DISCHARGE LINE SENSOR FROM RODENT CHEWING THROUGH THE WIRES. WIRING ASSEMBLY NEEDS REPLACEMENT TO RUN SYESTEM AND WEATHER MASTERS WILL PERFORM INSPECTION AT THAT TIME

Near N 100th Ave, Scottsdale, AZ 85266
Keith H.

Keith H.

WEATHER MASTERS PROPOSES TO REMOVE AND REPLACE THE CONDENSER FAN MOTOR BRACKET. THE CURRANT BRACKET IS BROCKEN AND MAY ALLOW THE MOTOR TO ROCK AND CAUSE DAMAGE TO THE MOTOR OR BLADE. 12-18-18 UPDATE PARTS ARE ON ORDER AND WILL BE DELIVERED TO THE OFFICE 5-7 DAYS SHIPPING 1-2-19 PARTS HAVE BEEN REPLACED. THE UNIT AT THIS TIME NO LONGER MAKES A NOISE . THE CONDENSER FAN MOTOR IS NOW SOLID TO THE UNIT WITH A GOOD GRILL/BRACKED.

Near N 81st St, Scottsdale, AZ 85251
Chris R.

Chris R.

INSTALL FILTER

Near E Pleasant Run, Scottsdale, AZ 85258
Ryan M.

Ryan M.

* Remove and haul away existing 2 ton split system * Install (1) new 2 ton cooling with 5 KW heat strips indoor unit * Install (1) new 2 ton A/C condenser on the roof * Reconnect indoor unit to existing duct, drain,refrigerant, high and low voltage lines * Install (1) new outdoor electrical service disconnect with fuses * Provide crane services to remove and install condenser on roof * Start up and ensure proper operation * Provide all labor and material to complete proposed work

Near E Pleasant Run, Scottsdale, AZ 85258
Keith H.

Keith H.

HOMEOWNER IS NOT HOME

Near N 111th Pl, Scottsdale, AZ 85262
Chris R.

Chris R.

Routine maintenance customer in Scottsdale, Arizona. Customer has a Trane, Armana, and a Rheem. Recommend carbon monoxide detector in the home. Systems show normal wear and tear for their ages no repairs needed at this time.

Near N Vía De Lago, Scottsdale, AZ 85258
Keith H.

Keith H.

PERFORM START UP ON SYSTEM. WEATHER MASTERS PERFORMED SYSTEM START UP . DIAGNOSIS: WEATHER MASTERS INSTALLED THE NEW EQUIPMENT BUT DID NOT INSTALL THE DUCT WORK. DURING THE START UP ON THE NEW EQUIPMENT, WEATHER MASTERS TESTED THE AIR FLOW OF THE NEW DUCT WORK. WEATHER MASTERS FOUND THE RETURN DUCT WORK TO BE TO SMALL AND NOT ALLOWING FOR CORRECT AIR FLOW. THE SYSTEM IS A 3TON SYSTEM AND THE AIR FLOW IS MOVING LESS THEN 1000 . URBAN BUILDERS WILL NEED TO HAVE THE DUCT WORK FIXED SO THE UNIT WILL WORK CORRECTLY. URBAN BUILDERS WILL CALL WEATHER MASTERS WHEN DUCT WORK IS FIXED .

Near E Gray Rd, Scottsdale, AZ 85260
Chris R.

Chris R.

PROBLEM PMP VISIT CARRIER 58PAV090-16 2299A08692 DIAGNOSIS TEMP RISE IS HIGH /THIS MAY CAUSE PREMATURE FAILURE OF THE HEAT EXCHANGER GAS PRESSURE IS TO HIGH/RECOMMEND ADJUSTING GAS PRESSURE 10 MFD RUN CAPACITOR IS WEAK /RECOMMEND REPLACING AT NEXT VISIT/CAP IS STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CHECKED ALL SAFTEY AND LIMIT SWITCHES /ALL FUNCTIONING AT THIS TIME UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE BUT HEATING AT THIS TIME REPAIRS ADJUSTED GAS VALVE PRESSURE TO 3.5 " WO

Near E Earll Dr, Scottsdale, AZ 85251