PROBLEM TRANE DIAGNOSIS BURNED /DAMAGED WIRES AT CONDENSER REPARED WIRES

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NO COOL TRANE DIAGNOSIS PLUGGED DRAIN/DUE TO DIRTY CONDENSATE DRAIN PAN THIS ISSUE WILL CONTINUE TO HAPPEN THE 115 V PUMP HAS TAKEN PERMANENT INTERNAL DAMAGE BECAUSE IT WAS RUNNING AND NOT ABLE TO PUMP THE WATER PUMP WAS SHUTTING THE UNIT WHEN THE SAFTEY SWITCH CLOSES BLEW THE DRAIN /BUT THE WILL HAPPEN AGAIN

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM WATER LEAK S.W COOLER DIAGNOSIS OVERFLOW PIPE MISSING INSTALLED OVERFLOW PIPE NO CHARGE

Near W Geneva Dr, Tempe, AZ 85282
Keith H.

Keith H.

REPLACED RETURN AIR FILTERS. 9) 8X20X1 29) 20X20X1 6) 16X25X1 1) 16X20X1 4)14X22X1 8) 16X24X2 2) 8X26.75X1 2) 20X30X1 TOTAL 61 FILTERS

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

Wo16745 Problem: Gas line for the heater is turned off by southwest gas a few yrs ago. THE WALL FURNACE IS DAMAGED DUE TO PAINT BEING SPRAYED ON THE HEAT EXCHANGER. THE FURNACE AS IT GETS HOT WILL START TO SMOKE. THE FURNACE SHOULD BE REPLACED BUT IF NOT IT WILL NEED TO BE PULLED APART AND CLEANED. THE HEAT EXHANGER MAY OR MAY NOT BE CLEANED ENOUGH TO KEEP THE UNIT FROM SMOKING. WEATHER MASTERS CAN NOT GUARRANTEE THE FUNCTION OF THE FURNACE AFTER CLEANING. THE FURNACE MAY STILL NEED TO BE REPLACED AFTER CLEANING.

Near S Kenwood Cir, Tempe, AZ 85281
Keith H.

Keith H.

PROBLEM: WATER DRIPPING ON THE FLOOR DIAGNOSIS: THE SYSTEM USES A CONDENSATE PUMP TO PUMP THE WATER OUT. THIS PUMP HAS FAILED TO OPPERATE. PUMP WILL NEED TO BE REPLACED. REPAIR; REPLACED 115V CONDENSATE PUMP WITH A NEW PUMP. TESTED NEW PUMP AND FLUSHED COPPER DRAIN LINE. UNIT IS NOW WORKING FINE.

Near S Priest Dr, Tempe, AZ 85282
Keith H.

Keith H.

**PERFORM 2O PT COOLER SERVICE ON 5 COMMERCIAL EVAP COOLERS. ** WEATHER MASTERS PERFORMED COOLER SERVICE ON 5 COMMERCIAL EVAP COOLERS. INCLUDES- - REPLACEING 3/8 WATER FLOAT VALVE. - REPLACING BLOWER DRIVE BELTS. - WASHING OUT COOLER WATER TUB. - ADJUSTING BELTS AND LUBING BLOWER SHAFT BEARINGS. - ADDING NEW SCALE ELIMINATING TABS. - ADJUSTING WATER FLOAT LEVELS. ADDITION TO COOLER SERVICE WEATHER MASTERS NEED TO DO THE FOLLOWING. - REPLACE 5 230V 25000 CFM COOLER WATER PUMPS. - REPLACE COOLER PUMP SCREANS. - REPLACE COOLER PADS DUE TO SCALE BUILD UP. 40 PADS. 8 PER COOLER. PERFORMED TEST ON EACH COOLER. CHECKING AMP DRAWS. AND WATER FLOW ACCROSS THE PADS. AT THIS TIME THE COOLER IS WORKING FINE. WEATHER MASTERS RECOMMENDS NEXT YEAR TO HAVE THE COOLERS RECOATED AND SEALED.

Near W Geneva Dr, Tempe, AZ 85282
Noel@acdudes.com

Noel@acdudes.com

WO # 16659 WEATHER MASTERS PROPOSES TO: REMOVE AND HAUL AWAY EXISTING FIRST CO. FAN COIL AND INSTALL NEW 2 TON FIRST CO. FAN COIL WITH R22 PISTON . WEATHER MASTERS WILL CONNECT NEW AIR HANDLER TO EXISTING FREON LINES ATTACHED TO EXISTING R22 CONDENSER. WEATHER MASTERS WILL FLUSH CONDENSATE AND CONNECT TO NEW AIR HANDLER. NOTE- THE OUTDOOR CONDENSER CAN BE REPLACED ALONG WITH CONVERTING NEW AIR HANDLER TO 410A AT A LATER DATE. WHEN SPACE FOR A NEW CONDENSER CAN BE MADE. WARRANTY- 5 YR PARTS ON FIRST CO AIR HANDLER

Near E Southern Ave, Tempe, AZ 85282
Keith H.

Keith H.

PROBLEM: NO COOL DIAGNOSIS: ROOFTOP CONDENSER HAS NOT POWER DUE TO A TRIPPED BREAKER. AFTER RESETING THE BREAKER I INSPECTED THE UNIT AND FOUND THE FREON PRESSURES TO BE HIGH. THE CONDENER COIL IS VERY DIRTY AND THIS WILL CAUSE THE COMPRESSOR TO OVER AMP AND POSSIBLE TRIP A BREAKER. THE CONDENSER FAN MOTOR IS SHOWING WEAR BUT NOT OVER AMPING AT THIS TIME. BERRINGS ARE NOT LOOSE . IT IS POSSIBLE THE OUTDOOR FAN MOTOR MAY BE OVER HEATING AND SHUTTING DOWN. RECOMMEND REPLACING THE MOTOR IF IT FAILS. REPAIR: RESET BREAKER AND HOSED OFF THE VERY DIRTY OUTDOOR COIL. FREON PRESSURES BACK TO NORMAL.COMPRESSOR AMPS NORMAL. SYSTEM IS COOLING AT THIS TIME.

Near S Priest Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

WEATHER MASTERS PERFORMED A 37 POINT INSPECTION ON THE TRANE PACKAGE UNIT AT THIS LOCATION. -PRESSURES WERE TESTED AND NORMAL - TEMPERATURE SPLIT IS AT THE OPTIMAL 20 DEGREE SPLIT - ELCTRICAL CONNECTIONS WERE TIGHTENED -AMPS ON INDOOR AND OUTDOOR FANS WERE CHECKED AND FOUND TO BE RUNNING NORMALLY -OUTDOOR FAN WAS FOUND TO HAVE NORMAL WEAR FOR ITS AGE -CAPACITORS WERE CHECKED AND ARE RUNNING NORMALLY THE UNIT IS RUNNING NORMALLY AT THIS TIME.

Near W Laguna Dr, Tempe, AZ 85282
Keith H.

Keith H.

WO16515 PROBLEM: WATER LEAKING. DIAGNOSIS: INDOOR AIR HANDLER FIRST CO. CEILING MOUNT FAN COIL IS LEAKING WATER FROM A RUSTED OUT CONDENSATE PAN. THE PAN AND COIL ARE SO RUSTED OUT THE DEBRIS MAY BE ALSO CLOGGING THE DRAIN. TO REPAIR THE PAN, THE ENTIRE AIR HANDLER WILL NEED TO BE DROPPED DOWN . THE PAN MAY NOT BE AVAILABLE DUE TO OLD AGE. THE PAN MAY NEED TO BE CUSTOM MADE. WEATHER MASTERS HIGHLY RECOMMENDS A NEW AIR HANDLER DUE TO THE OVERALL AGE AND CONDITION. NOTE THE OUTDOOR UNIT IS SHOWING HEAVY WEAR , HOWEVER A NEW CONDENSER WILL NOT FIT IN THE CURRENT SPACE NEXT TO THE EQUIPMENT. TWO TON STRAIGHT COOL WITH ELECTRIC HEAT STRIP . WEATHER MASTERS RECOMMENDS REPLACING WITH NEW 2 TON FIRST CO. AIR HANDLER AND INSTALLING A NEW CONDENSER AT A LATER DATE. REPAIR OPTION- WEATHER MASTERS WOULD NEED TO PULL AND REMOVE THE AIRHANDLER BEFORE THE REPAIR COULD BE MADE. WEATHER MASTERS WOULD NEED TO REMOVE THE OLD PAN AND HAVE A METAL SHOP FABRICATE A NEW PAN. WEATHER MASTERS WOU

Near E Southern Ave, Tempe, AZ 85282
Stuart M.

Stuart M.

PROBLEM: SYSTEM AND THERMOSTAT TURNING OFF INTERMITENTLY. DIAGNOSIS: LOSE WIRE TERMINAL IN THERMOSTAT. WEATHER MASTERS RECOMMENDS REPLACING THERMOSTAT. REPAIR: REPLACED THERMOSTAT. THERMOSTAT IS UNDER WARRANTY. THE UNIT IS RUNNING NORMALLY AT THIS TIME.

Near W Geneva Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

PERFORMED FIRST PMP INSPECTION ON ONE SPLIT HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COIL CLEANED OUTDOOR COIL TIGHTENED ELECTRICAL CONNECTIONS CHECKED FREON LEVELS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near S Mae Pl, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NO COOL TRANE 2TTR2036A1000AA 2414N083F MFD:10/2002 CONDENSER FAN MOTOR IS INTERNALLY DAMAGED 50/5 DUAL RUN CAPACITOR HAS FAILED COMPRESSOR HAS TAKEN PERMANENT INTERNAL DAMAGE WE NEED TO MAKE REPAIRS BEFORE WE CAN DUE FURTHER DIAGNOSTICS WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM 1/8 HP 1075 RPM CONDENSER FAN MOTOR /50/5 DUAL RUN CAPACITOR COMPRESSOR CONTACTOR IS BURNED AND PITTED MAY FAIL THIS SUMMER HOUSE IS TO HOT TO VERIFY CHARGE AT THIS TIME

Near S Priest Dr, Tempe, AZ 85282
Keith H.

Keith H.

PMP 37PT INSPECTION. DIAGNOSIS: SYSTEM IS RUNNING NORMAL AT THIS TIME. TESTED UNIT IN COOLING. TIGHTEN ELECTRICAL CONNECTIONS. HOSED OFF THE OUTDOOR COIL AND FLUSHED THE CONDENSATE LINE. UNIT SHOWING NORMAL WEAR DUE TO AGE. NOTE: DUE TO THE HOMEOWNER BEING A SMOKER THE AIR HANDLER HAS SMOKE/TAR COATING ON THE INSIDE OF THE AIR HANDLER. AT THIS TIME IT IS NOT EFFECTING THE SYSTEM THAT I CAN SEE. UNIT COOLING WITH A 20+ DEGREE SPLIT.

Near E Paseo Way, Tempe, AZ 85283
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON PACKAGE HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. UNIT IS SHOWING SOME RUST CORROSION ON INDOOR COIL AND SOME FINE DUST VISIBLE ON COIL. BOTH ARE NORMAL DUE TO AGE OF UNIT. OUTDOOR FAN MOTOR SHOWING WEATHER DAMAGE ALSO DUE TO AGE. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL TO KEEP AN EYE ON ALL PREVIOUSLY STATED FINDINGS AND POSSIBLE NEW RECOMMENDATIONS

Near S Mill Ave, Tempe, AZ 85282
Keith H.

Keith H.

Weather masters proposes to remove and replace the outdoor DEFROST control board. Weather masters proposes to remove and replace the 1.5 pole 40 amp contactor. Nordyne. Model ft4b-060k Serial ftd090200424 REPAIR: REMOVED AND REPLACED DEFROST CONTROL BOARD. AND 1.5 POLE CONTACTOR. PERFORMED TEST FUCTION OF NEW BOARD AND CONTACTOR. UNIT IS WORKING NORMAL AT THIS TIME.

Near W Caroline Ln, Tempe, AZ 85284
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE REPLACED 10@20-20

Near W Geneva Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON PACKAGE HEAT PUMP UNIT TESTED AMP DRAW OF MOTORS CHECKED RUN CAPACITORS FOR PERFORMANCE WITHIN MANUFACTURER'S RATING VERIFIED TEMPERATURE SPLIT ACROSS COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT HAD LOW 5MF RUN CAPACITOR FOR OUTDOOR FAN MOTOR TESTING AT 3.7MF CAUSING EXTRA WEAR TO THE MOTOR. CAPACITOR WAS REPLACED AT TIME OF INSPECTION AND UNIT RUNNING NORMALLY IN COOLING.

Near S Country Club Way, Tempe, AZ 85282
Stuart M.

Stuart M.

INSPECTED INSIDE FOR A LEAK. MOISTURE WAS FOUND RUNNING BETWEEN THE DUCT AND INSULATION ON THE UNDERSIDE. AFTER FURTHER INSPECTION ON THE OUTDOOR UNIT, A POSSIBLE LEAK WAS FOUND IN THE SEALANT CONNECTIONG THE TRANSITION DUCT WORK TO THE ROOF, UNDERNEATH THE AC DUCTWORK. INFORMED THE CUSTOMER THAT THEY WOULD NEED TO CONTACT A ROOFER TO SEAL THE ROOF TO STOP THE LEAK.

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

UNIT 8- TEDDY LOUNGE, DEFROST CONTROL BOARD THATS NOT WORKING. Unit 21- / defrost board and sensor bad

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

PMP INSPECTION. 2 UNITS. DIAGNOSIS: CHECKED AMP DRAWS ON OUTDOOR AND INDOOR UNITS. CLEANED OUTDOOR COILS WITH WATER. CHECKED PRESSURES AND REFRIGERANT LEVELS ON BOTH UNITS. REFRIGERANT LEVELS ARE OK. LEAK CHECKED CONDENSATE LINES AND PANS. TIGHTENED ELECTRICAL CONNECTIONS. VERIFIED SEQUENCE OF OPERATIONS IN BOTH HEATING AND COOLING. BOTH SYSTEMS SHOWING NORMAL WEAR FOR AGE. RECOMMEND: NEXT SERVICE IN THE FALL.

Near S Grandview Dr, Tempe, AZ 85284
Chris R.

Chris R.

PROBLEM NO COOL #15981 TRANE YCY042G1M0AD 5424LWL1H MFD:10/2005 DIAGNOSIS INDOOR BLOWER MOTOR HAS FAILED /THIS HAS ALLOWED PERMANENT INTERNAL DAMAGE TO THE COMPRESSOR EVAPORATOR COIL IS RUSTED AND DIRTY INDOOR BLOWER MOTOR IS DIRTY DRAIN PAN IS FULL OF DIRT AND DEBRIS THIS UNIT HAS A VARIABLE SPEED BLOWER MOTOR /RUNNING THIS MOTOR WITH A DIRTY COIL AND OR DIRTY BLOWER WHEEL WILL CAUSE INTERNAL DAMAGE TO THE MOTOR WE RECOMMEND CLEANING THE COIL,BLOWER WHEEL AND DRAIN PAN ALONG WITH THE MOTOR REPLACEMENT **DUE TO THE AGE AND CONDITION OF THIS UNIT WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM

Near S Terrace Rd, Tempe, AZ 85282
Stuart M.

Stuart M.

PROBLEM: UNIT NOT HEATING DIAGNOSIS: UNIT HAS A BAD THERMOSTAT ATTACHED TO SYSTEM. WEATHER MASTERS WAS ABLE TO FIRE UP THE UNIT BY BYPASSING THERMOSTAT INDICATING NO OTHER ISSUES WERE PRESENT. MANAGEMENT AT THE APARTMENT WAS INFORMED OF THE DIAGNOSIS AND WISHES TO HAVE IN HOUSE TECHNICIANS REMOVE AND REPLACE THERMOSTAT.

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NOISE #15666 DIAGNOSIS FILTER IS CAUSING THE NOISE/RECOMMEND LESS RESTRICTIVE FILTER

Near S Granada Dr, Tempe, AZ 85282