Tempe, AZ — Plumbing, Heating and Air Conditioning Service

Weather Masters, Inc. provides plumbing, heatingĀ  & Air Conditioning repair and installation services in Tempe, AZ and surrounding areas.

Check out what some of our customers are saying about Weather Masters, Inc.

Local Reviews
for Tempe, AZ

Weather Masters, Inc. Rated 5.0 out of 5 stars based on 3 customer reviews

Map of Tempe, AZ

Great




Review of Weather Masters, Inc.


Map of Tempe, AZ

Very informative




Review of Weather Masters, Inc.

Keith is awesome. Walked me through everything. Eased anxiety about price. Earned a loyal customer now.


Map of Tempe, AZ

We love Keith, We love Weather Masters




Review of Weather Masters, Inc.

Been Weather Masters customers for over four years now, and we especially live when Keith comes out to expertly diagnose our needs and explain solutions. Thanks!


Chris R.

Chris R.

PROBLEM TRANE DIAGNOSIS BURNED /DAMAGED WIRES AT CONDENSER REPARED WIRES

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NO COOL TRANE DIAGNOSIS PLUGGED DRAIN/DUE TO DIRTY CONDENSATE DRAIN PAN THIS ISSUE WILL CONTINUE TO HAPPEN THE 115 V PUMP HAS TAKEN PERMANENT INTERNAL DAMAGE BECAUSE IT WAS RUNNING AND NOT ABLE TO PUMP THE WATER PUMP WAS SHUTTING THE UNIT WHEN THE SAFTEY SWITCH CLOSES BLEW THE DRAIN /BUT THE WILL HAPPEN AGAIN

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM WATER LEAK S.W COOLER DIAGNOSIS OVERFLOW PIPE MISSING INSTALLED OVERFLOW PIPE NO CHARGE

Near W Geneva Dr, Tempe, AZ 85282
Keith H.

Keith H.

REPLACED RETURN AIR FILTERS. 9) 8X20X1 29) 20X20X1 6) 16X25X1 1) 16X20X1 4)14X22X1 8) 16X24X2 2) 8X26.75X1 2) 20X30X1 TOTAL 61 FILTERS

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

Wo16745 Problem: Gas line for the heater is turned off by southwest gas a few yrs ago. THE WALL FURNACE IS DAMAGED DUE TO PAINT BEING SPRAYED ON THE HEAT EXCHANGER. THE FURNACE AS IT GETS HOT WILL START TO SMOKE. THE FURNACE SHOULD BE REPLACED BUT IF NOT IT WILL NEED TO BE PULLED APART AND CLEANED. THE HEAT EXHANGER MAY OR MAY NOT BE CLEANED ENOUGH TO KEEP THE UNIT FROM SMOKING. WEATHER MASTERS CAN NOT GUARRANTEE THE FUNCTION OF THE FURNACE AFTER CLEANING. THE FURNACE MAY STILL NEED TO BE REPLACED AFTER CLEANING.

Near S Kenwood Cir, Tempe, AZ 85281
Keith H.

Keith H.

PROBLEM: WATER DRIPPING ON THE FLOOR DIAGNOSIS: THE SYSTEM USES A CONDENSATE PUMP TO PUMP THE WATER OUT. THIS PUMP HAS FAILED TO OPPERATE. PUMP WILL NEED TO BE REPLACED. REPAIR; REPLACED 115V CONDENSATE PUMP WITH A NEW PUMP. TESTED NEW PUMP AND FLUSHED COPPER DRAIN LINE. UNIT IS NOW WORKING FINE.

Near S Priest Dr, Tempe, AZ 85282
Keith H.

Keith H.

**PERFORM 2O PT COOLER SERVICE ON 5 COMMERCIAL EVAP COOLERS. ** WEATHER MASTERS PERFORMED COOLER SERVICE ON 5 COMMERCIAL EVAP COOLERS. INCLUDES- - REPLACEING 3/8 WATER FLOAT VALVE. - REPLACING BLOWER DRIVE BELTS. - WASHING OUT COOLER WATER TUB. - ADJUSTING BELTS AND LUBING BLOWER SHAFT BEARINGS. - ADDING NEW SCALE ELIMINATING TABS. - ADJUSTING WATER FLOAT LEVELS. ADDITION TO COOLER SERVICE WEATHER MASTERS NEED TO DO THE FOLLOWING. - REPLACE 5 230V 25000 CFM COOLER WATER PUMPS. - REPLACE COOLER PUMP SCREANS. - REPLACE COOLER PADS DUE TO SCALE BUILD UP. 40 PADS. 8 PER COOLER. PERFORMED TEST ON EACH COOLER. CHECKING AMP DRAWS. AND WATER FLOW ACCROSS THE PADS. AT THIS TIME THE COOLER IS WORKING FINE. WEATHER MASTERS RECOMMENDS NEXT YEAR TO HAVE THE COOLERS RECOATED AND SEALED.

Near W Geneva Dr, Tempe, AZ 85282
Noel@acdudes.com

Noel@acdudes.com

WO # 16659 WEATHER MASTERS PROPOSES TO: REMOVE AND HAUL AWAY EXISTING FIRST CO. FAN COIL AND INSTALL NEW 2 TON FIRST CO. FAN COIL WITH R22 PISTON . WEATHER MASTERS WILL CONNECT NEW AIR HANDLER TO EXISTING FREON LINES ATTACHED TO EXISTING R22 CONDENSER. WEATHER MASTERS WILL FLUSH CONDENSATE AND CONNECT TO NEW AIR HANDLER. NOTE- THE OUTDOOR CONDENSER CAN BE REPLACED ALONG WITH CONVERTING NEW AIR HANDLER TO 410A AT A LATER DATE. WHEN SPACE FOR A NEW CONDENSER CAN BE MADE. WARRANTY- 5 YR PARTS ON FIRST CO AIR HANDLER

Near E Southern Ave, Tempe, AZ 85282
Keith H.

Keith H.

PROBLEM: NO COOL DIAGNOSIS: ROOFTOP CONDENSER HAS NOT POWER DUE TO A TRIPPED BREAKER. AFTER RESETING THE BREAKER I INSPECTED THE UNIT AND FOUND THE FREON PRESSURES TO BE HIGH. THE CONDENER COIL IS VERY DIRTY AND THIS WILL CAUSE THE COMPRESSOR TO OVER AMP AND POSSIBLE TRIP A BREAKER. THE CONDENSER FAN MOTOR IS SHOWING WEAR BUT NOT OVER AMPING AT THIS TIME. BERRINGS ARE NOT LOOSE . IT IS POSSIBLE THE OUTDOOR FAN MOTOR MAY BE OVER HEATING AND SHUTTING DOWN. RECOMMEND REPLACING THE MOTOR IF IT FAILS. REPAIR: RESET BREAKER AND HOSED OFF THE VERY DIRTY OUTDOOR COIL. FREON PRESSURES BACK TO NORMAL.COMPRESSOR AMPS NORMAL. SYSTEM IS COOLING AT THIS TIME.

Near S Priest Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

WEATHER MASTERS PERFORMED A 37 POINT INSPECTION ON THE TRANE PACKAGE UNIT AT THIS LOCATION. -PRESSURES WERE TESTED AND NORMAL - TEMPERATURE SPLIT IS AT THE OPTIMAL 20 DEGREE SPLIT - ELCTRICAL CONNECTIONS WERE TIGHTENED -AMPS ON INDOOR AND OUTDOOR FANS WERE CHECKED AND FOUND TO BE RUNNING NORMALLY -OUTDOOR FAN WAS FOUND TO HAVE NORMAL WEAR FOR ITS AGE -CAPACITORS WERE CHECKED AND ARE RUNNING NORMALLY THE UNIT IS RUNNING NORMALLY AT THIS TIME.

Near W Laguna Dr, Tempe, AZ 85282
Keith H.

Keith H.

WO16515 PROBLEM: WATER LEAKING. DIAGNOSIS: INDOOR AIR HANDLER FIRST CO. CEILING MOUNT FAN COIL IS LEAKING WATER FROM A RUSTED OUT CONDENSATE PAN. THE PAN AND COIL ARE SO RUSTED OUT THE DEBRIS MAY BE ALSO CLOGGING THE DRAIN. TO REPAIR THE PAN, THE ENTIRE AIR HANDLER WILL NEED TO BE DROPPED DOWN . THE PAN MAY NOT BE AVAILABLE DUE TO OLD AGE. THE PAN MAY NEED TO BE CUSTOM MADE. WEATHER MASTERS HIGHLY RECOMMENDS A NEW AIR HANDLER DUE TO THE OVERALL AGE AND CONDITION. NOTE THE OUTDOOR UNIT IS SHOWING HEAVY WEAR , HOWEVER A NEW CONDENSER WILL NOT FIT IN THE CURRENT SPACE NEXT TO THE EQUIPMENT. TWO TON STRAIGHT COOL WITH ELECTRIC HEAT STRIP . WEATHER MASTERS RECOMMENDS REPLACING WITH NEW 2 TON FIRST CO. AIR HANDLER AND INSTALLING A NEW CONDENSER AT A LATER DATE. REPAIR OPTION- WEATHER MASTERS WOULD NEED TO PULL AND REMOVE THE AIRHANDLER BEFORE THE REPAIR COULD BE MADE. WEATHER MASTERS WOULD NEED TO REMOVE THE OLD PAN AND HAVE A METAL SHOP FABRICATE A NEW PAN. WEATHER MASTERS WOU

Near E Southern Ave, Tempe, AZ 85282
Stuart M.

Stuart M.

PROBLEM: SYSTEM AND THERMOSTAT TURNING OFF INTERMITENTLY. DIAGNOSIS: LOSE WIRE TERMINAL IN THERMOSTAT. WEATHER MASTERS RECOMMENDS REPLACING THERMOSTAT. REPAIR: REPLACED THERMOSTAT. THERMOSTAT IS UNDER WARRANTY. THE UNIT IS RUNNING NORMALLY AT THIS TIME.

Near W Geneva Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

PERFORMED FIRST PMP INSPECTION ON ONE SPLIT HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COIL CLEANED OUTDOOR COIL TIGHTENED ELECTRICAL CONNECTIONS CHECKED FREON LEVELS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.

Near S Mae Pl, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NO COOL TRANE 2TTR2036A1000AA 2414N083F MFD:10/2002 CONDENSER FAN MOTOR IS INTERNALLY DAMAGED 50/5 DUAL RUN CAPACITOR HAS FAILED COMPRESSOR HAS TAKEN PERMANENT INTERNAL DAMAGE WE NEED TO MAKE REPAIRS BEFORE WE CAN DUE FURTHER DIAGNOSTICS WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM 1/8 HP 1075 RPM CONDENSER FAN MOTOR /50/5 DUAL RUN CAPACITOR COMPRESSOR CONTACTOR IS BURNED AND PITTED MAY FAIL THIS SUMMER HOUSE IS TO HOT TO VERIFY CHARGE AT THIS TIME

Near S Priest Dr, Tempe, AZ 85282
Keith H.

Keith H.

PMP 37PT INSPECTION. DIAGNOSIS: SYSTEM IS RUNNING NORMAL AT THIS TIME. TESTED UNIT IN COOLING. TIGHTEN ELECTRICAL CONNECTIONS. HOSED OFF THE OUTDOOR COIL AND FLUSHED THE CONDENSATE LINE. UNIT SHOWING NORMAL WEAR DUE TO AGE. NOTE: DUE TO THE HOMEOWNER BEING A SMOKER THE AIR HANDLER HAS SMOKE/TAR COATING ON THE INSIDE OF THE AIR HANDLER. AT THIS TIME IT IS NOT EFFECTING THE SYSTEM THAT I CAN SEE. UNIT COOLING WITH A 20+ DEGREE SPLIT.

Near E Paseo Way, Tempe, AZ 85283
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON PACKAGE HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. UNIT IS SHOWING SOME RUST CORROSION ON INDOOR COIL AND SOME FINE DUST VISIBLE ON COIL. BOTH ARE NORMAL DUE TO AGE OF UNIT. OUTDOOR FAN MOTOR SHOWING WEATHER DAMAGE ALSO DUE TO AGE. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL TO KEEP AN EYE ON ALL PREVIOUSLY STATED FINDINGS AND POSSIBLE NEW RECOMMENDATIONS

Near S Mill Ave, Tempe, AZ 85282
Keith H.

Keith H.

Weather masters proposes to remove and replace the outdoor DEFROST control board. Weather masters proposes to remove and replace the 1.5 pole 40 amp contactor. Nordyne. Model ft4b-060k Serial ftd090200424 REPAIR: REMOVED AND REPLACED DEFROST CONTROL BOARD. AND 1.5 POLE CONTACTOR. PERFORMED TEST FUCTION OF NEW BOARD AND CONTACTOR. UNIT IS WORKING NORMAL AT THIS TIME.

Near W Caroline Ln, Tempe, AZ 85284
Chris R.

Chris R.

PROBLEM FILTER MAINTENANCE REPLACED 10@20-20

Near W Geneva Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

PERFORMED 37 POINT INSPECTION ON PACKAGE HEAT PUMP UNIT TESTED AMP DRAW OF MOTORS CHECKED RUN CAPACITORS FOR PERFORMANCE WITHIN MANUFACTURER'S RATING VERIFIED TEMPERATURE SPLIT ACROSS COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT HAD LOW 5MF RUN CAPACITOR FOR OUTDOOR FAN MOTOR TESTING AT 3.7MF CAUSING EXTRA WEAR TO THE MOTOR. CAPACITOR WAS REPLACED AT TIME OF INSPECTION AND UNIT RUNNING NORMALLY IN COOLING.

Near S Country Club Way, Tempe, AZ 85282
Stuart M.

Stuart M.

INSPECTED INSIDE FOR A LEAK. MOISTURE WAS FOUND RUNNING BETWEEN THE DUCT AND INSULATION ON THE UNDERSIDE. AFTER FURTHER INSPECTION ON THE OUTDOOR UNIT, A POSSIBLE LEAK WAS FOUND IN THE SEALANT CONNECTIONG THE TRANSITION DUCT WORK TO THE ROOF, UNDERNEATH THE AC DUCTWORK. INFORMED THE CUSTOMER THAT THEY WOULD NEED TO CONTACT A ROOFER TO SEAL THE ROOF TO STOP THE LEAK.

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

UNIT 8- TEDDY LOUNGE, DEFROST CONTROL BOARD THATS NOT WORKING. Unit 21- / defrost board and sensor bad

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

PMP INSPECTION. 2 UNITS. DIAGNOSIS: CHECKED AMP DRAWS ON OUTDOOR AND INDOOR UNITS. CLEANED OUTDOOR COILS WITH WATER. CHECKED PRESSURES AND REFRIGERANT LEVELS ON BOTH UNITS. REFRIGERANT LEVELS ARE OK. LEAK CHECKED CONDENSATE LINES AND PANS. TIGHTENED ELECTRICAL CONNECTIONS. VERIFIED SEQUENCE OF OPERATIONS IN BOTH HEATING AND COOLING. BOTH SYSTEMS SHOWING NORMAL WEAR FOR AGE. RECOMMEND: NEXT SERVICE IN THE FALL.

Near S Grandview Dr, Tempe, AZ 85284
Chris R.

Chris R.

PROBLEM NO COOL #15981 TRANE YCY042G1M0AD 5424LWL1H MFD:10/2005 DIAGNOSIS INDOOR BLOWER MOTOR HAS FAILED /THIS HAS ALLOWED PERMANENT INTERNAL DAMAGE TO THE COMPRESSOR EVAPORATOR COIL IS RUSTED AND DIRTY INDOOR BLOWER MOTOR IS DIRTY DRAIN PAN IS FULL OF DIRT AND DEBRIS THIS UNIT HAS A VARIABLE SPEED BLOWER MOTOR /RUNNING THIS MOTOR WITH A DIRTY COIL AND OR DIRTY BLOWER WHEEL WILL CAUSE INTERNAL DAMAGE TO THE MOTOR WE RECOMMEND CLEANING THE COIL,BLOWER WHEEL AND DRAIN PAN ALONG WITH THE MOTOR REPLACEMENT **DUE TO THE AGE AND CONDITION OF THIS UNIT WEATHER MASTERS RECOMMENDS REPLACING THE SYSTEM

Near S Terrace Rd, Tempe, AZ 85282
Stuart M.

Stuart M.

PROBLEM: UNIT NOT HEATING DIAGNOSIS: UNIT HAS A BAD THERMOSTAT ATTACHED TO SYSTEM. WEATHER MASTERS WAS ABLE TO FIRE UP THE UNIT BY BYPASSING THERMOSTAT INDICATING NO OTHER ISSUES WERE PRESENT. MANAGEMENT AT THE APARTMENT WAS INFORMED OF THE DIAGNOSIS AND WISHES TO HAVE IN HOUSE TECHNICIANS REMOVE AND REPLACE THERMOSTAT.

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NOISE #15666 DIAGNOSIS FILTER IS CAUSING THE NOISE/RECOMMEND LESS RESTRICTIVE FILTER

Near S Granada Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NOISE #15666 DIAGNOSIS FILTER IS CAUSING THE NOISE/RECOMMEND LESS RESTRICTIVE FILTER

Near S Granada Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NOISE #15666 DIAGNOSIS FILTER IS CAUSING THE NOISE/RECOMMEND LESS RESTRICTIVE FILTER

Near S Granada Dr, Tempe, AZ 85282
Keith H.

Keith H.

WEATHER MASTERS WILL REMOVE AND REPLACE WARRANTY COMPRESSOR. WEATHER MASTERS WILL INSTALL NEW BI FLOW FILTER DRIER, RUN CAPACITOR AND START CAPACITOR, WEATHER MASTERS WILL USE 9 LBS OF NEW F410A FREON .

Near S Farmer Ave, Tempe, AZ 85283
Keith H.

Keith H.

PROBLEM: FREEE SECOND OPINION. DIAGNOSIS: 3 TON PACKAGE HEAT PUMP SYSTEM NOT HEATING OR COOLING. THE COMPRESSOR HAS A FAILED CAPACITOR. BURNED UP START DISC AND A LOCKED UP COMPRESSOR. THE COMPRESSOR WILL NEED TO BE REPLACED IN ORDER TO RESTORE FUCTION TO THE SYTEM. WEATHER MASTERS WILL PROVIDE ESTIMATE FOR REPAIRS. NORDYNE MODEL - Q7RD-036K SERIAL Q7F141060077

Near S Farmer Ave, Tempe, AZ 85283
Chris R.

Chris R.

CHECKED UNIT UNIT IS SHOWING WEAR DUE TO AGE AND USAGE 45/5 DUAL RUN CAPACITOR IS OK AT THIS TIME AMPS FOR ALL MOTORS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME TESTED DEFROST CYCLE /NO ISSUES AT THIS TIME CONDENSER FAN MOTOR IS SHOWING WEATHER WEAR THE UNIT IS HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS THE EVAPORATOR COIL CHECKED THE SEAL ON THE DUCT AT THE UNIT /NO ISSUES ANY OTHER ISSUES WE RECOMMEND A ROOFER

Near E Loma Vista Dr, Tempe, AZ 85282
Stuart M.

Stuart M.

Perform heating inspections on HVAC equipment. Unit 1 - Low/Weak 5MFD Outdoor fan motor UNIT 8- TEDDY LOUNGE, UNIT HAS A WEAK 3MFD CAPACITOR AND A DEFROST CONTROL BOARD THATS NOT WORKING. Unit 9- weak 10 cap UNIT 10- UNIT HAS A ODF MOTOR THAT IS OVER AMPING . RECOMMEND REPLACEMENT. UNIT 18- WEAK 5MFD CAPACITOR , ODF MOTOR OVER AMPING. RECOMMEND REPLACEMENT. Unit 21- weak 45-5 cap / defrost board and sensor bad UNIT 23 - ODF MOTOR LEAKING OIL AND OVER AMPING. RECOMMEND REPLACING MOTOR Class 4- 55-5 weak / split system Unit 11 and 12 weak 10-10 dual caps

Near S Rural Rd, Tempe, AZ 85283
Chris R.

Chris R.

#15623 /NOISE S/A REGISTER ADJUSTABLE DAMPER IS VIBRATING/RECOMMEND REPLACING 12/6 SIDEWALL TENANT NOT HOME TO VERIFY ISSUE/NEIGHBOR GAVE ME ACCESS REPAIRS ADJUSTED DAMPER AND NOISE STOPPED FOR NOW WILL PROVIDE ESTIMATE APPON REQUEST

Near S Granada Dr, Tempe, AZ 85282
Chris R.

Chris R.

NEED TO RESCHEDULE - Chris arrived and customer was mistaken that we were only coming out to look at the Pigeon issue and not perform the PMP yet. PMP VISIT 1 UNIT GOODMAN PHKJ048-1C 0408089629 DIAGNOSIS UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT IS HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS EVAPORATOR COIL TESTED DEFROST CYCLE /NO ISSUES AT THIS TIME TESTED 60/5 DUAL RUN CAPACITOR /SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CHECKED ALL MOTOR AMPS /ALL ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME

Near E Don Carlos, Tempe, AZ 85281
Chris R.

Chris R.

Perform heating inspections on HVAC equipment. WEATHER MASTERS TIGHTEN ELECTRICAL CONNECTIONS, TESTED FREON LEVELS AND MOTOR AMP DRAWS, WEATHER MASTERS INSPECTED INDOOR AND OUTDOOR COILS. WEATHER MASTERS TESTED HEATING DEFROST CYCLE SEQUENCE OF OPPERATION. ALL OF THE UNITS ARE RUNNING IN HEATING AND SOME UNITS HAVE ISSUES. LIST OF RECOMMENDED REPAIRS ARE TO LIMIT HEATING AND COOLING FAILURES IN THE FUTURE. RECOMMENED REPAIRS- Unit 1 - low weak 5mfd for outdoor fan motor Unit2- system is very old. Compressor is noisy. Recommend unit replacement Unit 3- unit compressor is noisy unit is very old. Recommend unit replacement UNIT 8- TEDDY LOUNGE, UNIT HAS A WEAK 3MFD CAPACITOR AND A DEFROST CONTROL BOARD THATS NOT WORKING. Unit 9- weak 10 cap UNIT 10- UNIT HAS A ODF MOTOR THAT IS OVER AMPING . RECOMMEND REPLACEMENT. UNIT 18- WEAK 5MFD CAPACITOR , ODF MOTOR OVER AMPING. RECOMMEND REPLACEMENT. Unit 21- weak 45-5 cap / defrost board and sensor bad UNIT 23 - ODF MOTOR LEAKING O

Near S Rural Rd, Tempe, AZ 85283
Chris R.

Chris R.

NEED TO RESCHEDULE

Near E Don Carlos, Tempe, AZ 85281
Keith H.

Keith H.

PROBLEM: EAST MPR ROOM RUNNING IN COOLING. DIAGNOSIS: THE SYSTEM WAS RUNNING IN COOLING , HOWEVER THE THERMOSTAT WAS SET IN HEAT. THE THERMOSTAT WAS SENDING THE WRONG SINGLE OUT. RECOMMEND REPLACING THE THERMOSTAT REPAIR: WEATHER MASTERS INSTALLED A NEW HONEYWELL 8000 REDLINK 2STAGE COOLING THERMOSTAT. THE SYSTEM IS NOW RUNNING IN HEATING JUST FINE WITH NO ISSUES.

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

wo15092 PROBLEM: INDOOR FAN NOT RUNNING IN HEATING.. ONLY IN A/C DIAGNOSIS: THE INDOOR FAN DOESNT START RUNNING UNTILL THE PRESSURES OF THE UNIT BUILD UP TO HEAT. IN AC THE FAN WILL TURN ON RIGHT AWAY BUT WILL NOT IN HEATING. AT THIS TIME THE UNIT WILL WORK IN HEATING JUST FINE. THE TENANT NEEDS TO LEAVE THE AIR HANDLER ON LONG ENOUGH TO ALLOW THE FAN TO TURN ON. FOR SOME MINI SPLITS THIS IS NORMAL.

Near S Hardy Dr, Tempe, AZ 85281
Chris R.

Chris R.

PROBLEM: ROOM 201 NOT KICKING ON. DIAGNOSIS: WHEN I ARRIVED THE ROOM WAS BEING USED AND COULDNT GET ACCESS. THE PERSON OPEN THE DOOR AND SAID THE UNIT WAS HEATING. I TALKED TO STEVE AND HE SAID TO CANCEL THE WORK ORDER. WEATHER MASTERS WILL STILL CHARGE A SERVICE CALL FEE FOR TRAVEL. DIAGNOSIS RM 201 FIRST CO. 513B024005BFC BTB718A100A1 232064U20 THE UNIT SHOWS A RESTRICTION AT THE EVAPORATOR POSSIBLE LOW CHARGE COMPRESSOR IS DAMAGED THE GUEST HAVE BEEN RUNNING THE UNIT IN LOW AMBIENT CONDITIONS DUE TO AGE AND CONDITION WE RECOMMEND REPLACING THE SYSTEM

Near S 48th St, Tempe, AZ 85281
Keith H.

Keith H.

PROBLEM: ROOM 201 NOT KICKING ON. DIAGNOSIS: WHEN I ARRIVED THE ROOM WAS BEING USED AND COULDNT GET ACCESS. THE PERSON OPEN THE DOOR AND SAID THE UNIT WAS HEATING. I TALKED TO STEVE AND HE SAID TO CANCEL THE WORK ORDER. WEATHER MASTERS WILL STILL CHARGE A SERVICE CALL FEE FOR TRAVEL.

Near S 48th St, Tempe, AZ 85281
Keith H.

Keith H.

PROBLEM: UNIT IS COOLILNG AND HEATING FINE. HOWEVER THE OUTDOOR UNIT EARLY IN THE MORNING MAKES A LOUD SWOOSH NOISE WHEN THEN SYSTEM TURNS OFF. DIAGNOSIS: WEATHER MASTES WAS ABLE TO REPLICATETEH NOISE WITH DEFROST CYCLE. THE HOMEOWNER SAID THIS IS WHAT HE HEARS. WEATHER MASTERS EXPLAINED HOW THE DEFROST CYCLE WORKS AND THE HOMEOWNER IS NOW AWARE. THE UNIT FREON PRESSURES AND TEMPATURES CHECK FINE AT TH IS TIME. NO ISSUES WITH THE EQUIPMENT RIGHT NOW.

Near E Stephens Dr, Tempe, AZ 85283
Chris R.

Chris R.

PROBLEM NO HEAT TRANE TUD080C948K2 3173PRD2G DIAGNOSIS VACUUM PRESSURE SWITCH IS TRIPPING DUE TO A FLUE PIPE RESTRICTION REPAIRS ADJUSTED FLUE PIPE CAP PRESSURE SWITCH MAY HAVE TAKEN INTERNAL DAMAGE BUT FURNACE IS OPERATING AT THIS TIME

Near S Priest Dr, Tempe, AZ 85282
Keith H.

Keith H.

Wo14966 REPAIR FREON LEAK LOCATED AT MECHANICAL FLAIR CONNECTION FOR INDOOR TXV VALVE,. THE MECHANICAL CONNECTIONS NEEDS TO BE REPAIRED. INCLUDES- -REPAIRING FLAIR CONNECTION BY REPLACING WITH A BRAZED CONNECTION. -REPLACING BIFLOW FILTER DRIER -PRESSURE TESTING THE SYSTEM -RECHARGEING THE UNIT WITH THE FACTORY RECOMMENDED FREON CHARGE OF 9.5LBS OF R410A.

Near E 5th St, Tempe, AZ 85281
Nicole  P.

Nicole P.

Noel went to look at the t-stat Unit was in defrost mode and needed time to defrost due the cold temperature outside. Unit is working at this time and is heating.

Near S Rural Rd, Tempe, AZ 85283
Keith H.

Keith H.

WO-14948 PROBLEM: NO HEAT DIAGNOSIS; THE UNIT IS LOW ON R410A FREON. WEATHER MASTERS WAS ABLE TO LOCATE A LEAK ON THE MECHANICAL CONNECTION FOR THE TXV PRESSURE TUBE. THE CONNECTION SHOULE BE REPLACED WITH A BRAZED CONNECTION TO ENSURE NO MORE LEAKS. WEATHER MASTERS WILL FORWARD ESTIMATE TO REPAIR CONNECTION. REPLACE BI FLOW DRIER , PRESSURE TEST SYSTEM. EVACUATE AND RECHARGE WITH NEW R410A FREON 9.5 LBS. THE LEAK WILL NEED TO BE REPAIRED BEFOR THE SYSTEM WILL HEAT OR COOL AGAIN.

Near E 5th St, Tempe, AZ 85281
Keith H.

Keith H.

UPSTAIRS DAY AND NIGHT N4H436GKG201 E160217127 FEM4X3600BL2 A155070264 THIS UNIT HAS A NO HASSEL WARRANTY DOWNSTAIRS DAY AND NIGHT UPSTAIRS UNIT WAS VERY LOW ON REFRIGERANT FOUND LEAK AT EVAPORATOR COIL 12-21-2018 WEATHER MASTERS REMOVED AND REPLACED THE INDOOR EVAP COIL UNDER PART WARRANTY. WEATHER MASTERS RECOVERED THE EXISTING R410A FREON . REMOVED AND REPLACED THE INDOOR EVAP COIL. THE NEW COIL DID NOT COME WITH A NEW TXV. WEATHER MASTERS WAS ABLE TO RE USE THE EXISTING TXV METER DEVICE AND CONDENSATE DRAIN PAN. WEATHER MASTERS PRESSURE TESTED . EVAUATED AND RECHARGED THE SYTEM WITH NEW R410A FREON. 8.98 LBS. WEATHER MASTERS WILL FOLLOW UP IN THE SPRING ON NEXT PMP VISIT TO VERIFY FREON CHARGE. THE SYSTEM NEEDS TO RUN IN COOLING TO ACCUATLY CHARGE THE SYSTEM TO 100% WEATHER MASTERS WILL ADJUST THE CHARGE IF NEEDED IN THE SPRING AT NO CHARGE.

Near E Brentrup Dr, Tempe, AZ 85283
Keith H.

Keith H.

AZ Prime WO#: 9006 Problem: No heat Repair: None. Tenant requested appointment between 4 - 6 pm on 12/27/17. Technician arrived at 4pm. Technician knocked on the door several times and called tenant but no one answered. Technician waited at property for 30 minutes and attempted contacting tenant again but still got no answer.

Near S Carney Ave, Tempe, AZ 85281
Chris R.

Chris R.

PROBLEM `PMP VISIT 2 UNITS ICP PHD548000KTP0C1 C132826038 DIAGNOSIS RUN CAPACITORS ARE SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CONDENSER FAN MOTOR IS LEAKING OIL BUT NOT OVER AMPING AT THIS TIME CHECK THE OPERATION OF THE DEFROST CYCLE /NO ISSUES AT THIS TIME VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS THE EVAPORATOR COIL NO RECOMMENDED REPAIRS AT THIS TIME GOETTL HP485J 02154214 DIAGNOSIS THE UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE RUN CAPACITORS ARE SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME CHECKED THE OPERATION OF THE DEFROST CYCLE /NO ISSUES AT THIS TIME VERIFIED SEQUENCE OF OPERATION IN HEATING MODE AND THE UNIT HEATING WITH A 25 DEGREE TEMP SPLIT ACROSS THE EVAPORATOR COIL NO RECOMMENDED REPAIRS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS

Near E Diamond Dr, Tempe, AZ 85283
Chris R.

Chris R.

PROBLEM NO HEAT TRANE TUD060C936K3 3033J7P2G DIAGNOSIS INDOOR BLOWER MOTOR HAS FAILED BLOWER WHEEL IS DIRTY POSSIBLE DIRTY EVAPORATOR COIL /CAN'T VERIFY WITHOUT REMOVING THE COIL REPAIRS REPLACED 115 VOLT INDOOR BLOWER MOTOR PULLED AND CLEANED BLOWER WHEEL VERIFIED SEQUENCE OF OPERATION IN THE HEATING MODE AND THE UNIT HEATING AT THIS TIME REPLACE OEM INDOOR BLOWER MOTOR PULL AND CLEAN BLOWER WHEEL

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM NO HEAT TRANE TUD060C936K3 3033J7P2G DIAGNOSIS INDOOR BLOWER MOTOR HAS FAILED BLOWER WHEEL IS DIRTY POSSIBLE DIRTY EVAPORATOR COIL /CAN'T VERIFY WITHOUT REMOVING THE COIL

Near S Priest Dr, Tempe, AZ 85282
Chris R.

Chris R.

PROBLEM #14516 NO COOL GOODMAN CKL42-1L 0507136540 DIAGNOSIS 40 MFD RUN CAPACITOR FOR THE COMPRESSOR HAS FAILED /COMPRESSOR HAS TAKEN PERMANENT INTERNAL DAMAGE THIS UNIT IS SHOWING HEAVY WEAR RECOMMEND REPLACING SOON REPAIRS REPLACED 40 MFD RUN CAPACITOR VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT THIS TIME

Near W Grove Pkwy, Tempe, AZ 85283